8.6
Connecting data cable
You can connect eStore for data communication as follows:
• to eCore via the CAN bus
• to PerfectCharge MCA charger via LIN/CI bus
• to PerfectCharge MCA charger via LIN/CI bus, through MPC01
Through the data link parameters such as voltage, temperature and charge level are
monitored and displayed. For more details, please refer to the relevant operating
instructions of the connected devices.
➤ Establish a data connection corresponding to your system configuration.
8.7

Connecting multiple eStores

Up to eight eStore can be connected in parallel to increase the total battery pack
capacity to up to 800 Ah. The figure shows an example of the data connections for
three connected eStores (fig. 6, page 4).
I
NOTE
• To connect multiple eStores, you need at least one BUS cable and
the eStore configuration kit (see chapter "Accessories" on page 12).
• Connected eStores must be set with the eStore Configurator (see
chapter "Connect BUS cable and configure" on page 20). If you only
use a single eStore, no configuration is required. eStore is factory-
adjusted to be used as a single battery.
• Make sure that all eStores are fully charged.
The first eStore serves as the master. It has the following functions:
• It controls the main switch of the other eStores (fig. 6, page 4).
• It connects to the chargers via data links (CAN/LIN).
The other eStores are controlled as slaves by the master.