4-7. Series Operation
For series operation, either method (A) or (B) is possible.
Method ( A )
Power
Supply
Output
Terminal
Output
Terminal
Method ( B )
Power
Supply
Output
Terminal
Output
Terminal
4-8. Isolation Test
Isolation resistance between output and
shall be more than 100M at 500VDC. For safety operation,
voltage setting of DC isolation tester must be done before
the test. Ensure that the unit is fully discharged after the test.
Output ~
(Protective Earth) : 500VDC 100M or more
AC(L)
AC(N)
Isolation
Tester
COM
4-9. Withstand Voltage
This series is designed to withstand 4243VDC between input
and output, 2500VDC between input and
Earth) and 707VDC between output and the
Earth) for 1 minute each. When testing withstand voltage, set
current limit of the withstand voltage test equipment to 20mA
(Output -
voltage must be gradually increased from zero to the testing
value and then gradually decreased for shut down. When timer
is used, the power supply may be damaged by high impulse
voltage at timer switch on and off. Connect input and output
as follows.
Load
Input ~ Output (dotted line )
Input ~
Load
Withstand
Load
Voltage
Tester
Output ~
(Protective Earth)
+
-
Withstand
DC
Voltage
Tester
OK
TDK-Lambda
DRB120 Series
INSTRUCTION MANUAL
(Protective Earth) : 100mA ). The applied
4243VDC 1min. ( 20mA )
(Protective Earth) (solid line )
2500VDC 1min. ( 20mA )
AC(L)
AC(N)
COM
(Protective Earth)
707VDC 1min. (100mA)
AC (L)
AC (N)
COM
(Protective
(Protective
+
-
DC
OK
+
-
DC
OK