PA634-04-01C
10. DRB120 series UL508 Listed Condition
WIRING
CONNECTOR
Recommended Wire
INPUT
10~24 AWG
(L, N,
)
OUTPUT
10~24 AWG
(+V, -V)
OUTPUT
10~24 AWG
(DC OK)
1) Wire requirement is rated at minimum 105°C and to use
copper conductor only.
2) For use in a Pollution degree 2 environment only.
3) These products are considered for use where maximum
surrounding air temperature does not exceed 70°C. When
installing these products please refer to section 7 for
derating.
4) For indoor use only.
Product marking:
TDK-Lambda Singapore Pte. Ltd.
(Sales, Services and R&D)
1008 Toa Payoh North #06-01/08, #07-01/03
Singapore 318996
Telephone: +65 62517211
Facsimile: +65 62509171
WEBSITE:
www.tdk-lambda.com.sg
Rated Torque
10.3 kgf.cm
(9 lbf.in)
10.3 kgf.cm
(9 lbf.in)
10.3 kgf.cm
(9 lbf.in)
Note : Name plate's contents shown in this instruction manual
is for reference only.
11. Before concluding that the unit is at fault...
Before concluding that the unit is at fault, make the
following checks:
Check if the rated input voltage is connected.
Check if the wiring of input and output is correct.
Check if the wire material is not too thin.
Check if the output voltage control ( V.ADJ ) is properly
adjusted.
Check if the output current and wattage is not over
specification.
Audible noise can be heard during dynamic-load operation.
Audible noise can be heard when input voltage waveform is
non-sinusoidal wave.
Audible noise can be heard during no or light load condition
where the unit entered into bursts mode operation.
12. Returns
Please contact your local sales office or visit our website to
arrange return of any faulty product.
TDK-Lambda
DRB120 Series
INSTRUCTION MANUAL