INTERFACE SPECIFICATIONS
RS485 termination switch settings (RS485 TEAMINATE)
Termination setting
If several multiplexers are being connected together, termination settings must also be made.
•
Set the RS485 termination switch on the rear panel to ON, and set the termination switch of the last device in the series to ON.
•
Be sure to set the RS485 termination switches of all devices in between (devices other than the first and last in the series) to OFF.
System controller
POWER
RS485
GND
A
B
12V DC IN
ON
A
B
ADDRESS
1 2 3
1
0
OFF
TERMINATE
Time lapse VCR
Command descriptions
Computer commands
Command
1 – 16 (90 – 9F)
MULTI (82)
QUAD (83)
PLUS (84)
SEQUENCE (87)
ZOOM (85)
STILL (86)
LIVE (80)
VCR (81)
SPOT MONITOR (88)
MENU (74)
+ (65), – (66)
j (54), l (64), c (63), d (53)
NEXT (75) ... NEXT button
EXIT (76) ... EXIT button
MENU RESET (E1)
CLOCK ADJUST (E0)
SECURITY LOCK ON (69)
SECURITY LOCK OFF (6A)
ON
Termination switch
OFF
RS485
TERMINATE
ON
OFF
RS485
TERMINATE
ON
OFF
ON
Termination switch
OFF
Switches the main monitor to display the specified camera image in a single-screen display.
Switches the main monitor images to multiple-screen display.
Switches the main monitor to 4-screen display.
Switches the main monitor image to plus screen display.
When main monitor is in single-screen display, automatically switches the images in single-screen display.
Zooms in on main monitor image.
Pauses the main monitor image.
Switches to live image mode.
Switches to video playback mode.
Enables spot monitor screen settings so that spot monitors can be used together with main monitor.
Displays the menu screen on the main monitor. Closes a menu if it is already displayed.
Changes a menu screen item setting (ON, OFF, etc.).
Selects menu screen items (moves cursor up/down/left/right).
Moves to setting sub-screen.
When a sub-screen is displayed, returns to the previous level.
Returns the selected item in a menu screen to the default setting.
Sets the clock display (minutes and seconds) to 00:00.
Sets a security lock.
Cancels a security lock.
Note: If the termination settings are not correct, data will be
reflected by either end of the series and this will affect
the transmission of other data, so that the data that is
transmitted to each device will not be correct.
Details
– 76 –
English