Descaling
Limescale deposits lead to energy loss and adversely affect the lifespan of the appliance as
well as the cooking results. The appliance switches off prematurely if the layer of limescale
is too thick. The limescale is then very difficult to remove.
Therefore descale the appliance regularly.
▪ Prior to descaling, unplug the appliance from the mains and allow it to cool down.
▪ Pour descaling agent into the heating bowl (3) and leave the appliance to stand until
the limescale has detached from the base.
▪ Then pour out the water and rinse thoroughly with cold tap water.
Do not heat the solution during descaling.
Caution: the warranty does not cover damage caused by failure to observe the descaling
instructions.
For UK use only
• This product is supplied with a 13 A plug conforming to BS 1363 fitted to the mains lead.
If the plug is unsuitable for your socket outlets or needs to be replaced, please note the
following. If the plug is a non-rewireable one, cut it from the mains lead and immediately
dispose of it. Never insert it into a socket outlet as there is a very great risk of an electric
shock.
• The replacement of the plug at the mains lead has to be done according to the following
instructions:
Warning - This appliance must be earthed!
Important: The wires in this mains lead are coloured in accordance with the following
code:
green/yellow
blue
brown
As the colours of the wires in the mains lead of this appliance may not correspond with the
coloured markings identifying the terminals in your plug, proceed as follows:
the wire which is coloured green and yellow must be connected to the terminal
which is marked with the letter E or by the earth symbol
green and yellow,
the wire which is coloured blue must be connected to the terminal which is marked
with the letter N or coloured black,
the wire which is coloured brown must be connected to the terminal which is
marked with the letter L or coloured red.
• If a 13 A (BS 1363) plug is used it must be fitted with a 3 A fuse conforming to BS 1362
and be ASTA approved. If any other type of plug is used, the appliance must be protected
by a 5 A fuse either in the plug or adapter or at the distribution board. If in doubt - consult
a qualified electrician.
• Never use the plug without closing the fuse cover.