OUTPUT BOARD
REV
OUT. PROC. 1
1.0
OUT. PROC. 2
1.0
OUT. PROC. 3
1.0
OUTPUT BOARD
REV
OUT. PROC. 4
1.0
OUT. PROC. 5
1.0
OUT. PROC. 6
1.0
To exit from the submenu, press ESC.
DETAIL OF ALARMS ON THE IO 3250 DIGITAL INPUT/OUTPUT BOARDS
SYSTEM ALARMS OVERVIEW
GPI PROCESSORS
DIG. CONSOLLES
PRESS F1 TO VIEW CURRENT ALARMS
For a detailed report on the current status of alarms related to the IO 3250 digital INPUT/OUTPUT boards, from the ALARMS menu of the
control unit, use the ↑ / ↓ and/or pag ↑ / pag ↓ keys to move the selection point to the GPI PROCESSORS submenu and press ENTER. The
fields described below appear on the control unit display.
GPI BOARD
Indicates the identification number of the IO 3250 digital INPUT/OUTPUT board (see the section CHARACTERISTIC PARA-
METERS).
REV
Indicates the software version of the digital INPUT/OUTPUT board.
DCI
Indicates an alarm caused by a communication problem between the board and the control unit. When the alarm is active,
the symbol X is shown in the field.
EEP
Indicates an alarm caused by a failure or defective operation of the board's EEPROM memory. When the alarm is active, the
symbol X is shown in the field.
RST
Indicates an alarm caused by the reset of the board microprocessor for reinitializing its operation ("watchdog" function).
When the alarm is active, the symbol X is shown in the field.
CFG
Indicates an alarm caused by incomplete configuration of the board on the part of the control unit (e.g. the configuration
was interrupted by board removal). When the alarm is active, the symbol X is shown in the field.
POW
Indicates an alarm caused by a power supply voltage to the board that is too low or absent. When the alarm is active, the
symbol X is shown in the field.
KO
Indicates an alarm caused by the removal of the board (e.g. to repair it). In this condition, the board no longer communica-
tes with the CP 3100 control unit, and the control of all the other alarms causes is suspended. To use the previously remo-
ved board again, the system must be reconfigured as described in the section STORING A CONFIGURATION. When the
alarm is active, the symbol X is shown in the field.
To display the subsequent or previous IO 3250 digital INPUT/OUTPUT boards, press the ↑ / ↓ and/or pag ↑ / pag ↓ keys.
GPI BOARD
REV
GPI PROC. 1
1.0
GPI PROC. 2
1.0
GPI PROC. 3
1.0
GPI BOARD
REV
GPI PROC. 4
1.0
GPI PROC. 5
1.0
GPI PROC. 6
1.0
To exit from the submenu, press ESC.
DCI
EEP
RST
CFG
Pag ↓
DCI
EEP
RST
CFG
DCI
EEP
RST
CFG
0
0
0
0
0
0
0
0
0
0
0
0
Pag ↓
DCI
EEP
RST
CFG
0
0
0
0
0
0
0
0
0
0
0
0
POW AUD
POW AUD
ALARMS
[
]
[
]
POW
KO
0
0
0
0
0
0
POW
KO
0
0
0
0
0
0
111