Fermax CITYLINE DUOX Serie Manual De Instalador Y Usuario página 33

Kit audio
Ocultar thumbs Ver también para CITYLINE DUOX Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DUO
DUO
DUO
DUO
DUOX CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
DUO
DUO
X CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
DUO
DUO
DUOX CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
IMPORTANT NOTE:
Programming the installer´s parameters.
You can not configure the buttons panel alone, since it does not have a keypad for entering
the numeric values. You must temporarily connect a keypad (ref. 7439) to change these
parameters (download the Direct Panels Programming Manual, cod. 97701) at
www.fermax.com.
In DIRECT Panel configurations (with keypad), for programming these parameters, you
must download the manual from our website.
When there is more than one panel in the installation, the ref. key 7439 is required to
program the panel number. See Quick Programming Guide at the end of this manual.
E)
Panel Connectors:
• System connection terminals:
B,B: DUOX bus: telephone, data and audio power.
C, NO, NC: relay contacts,
+12: output12 Vdc-250mA
BS, -: entrance hall button.
S, -: door sensor input.
+, GND: 18 V DC input
P1-P2: button connections
F)
CN2
Individual connection buttons for continuous profile Cityline panel
G)
CN3
OneToOne Module Connection
H)
Select language for «open door» message.
A
B
C
D
E
F
I)
Adjust
the
audio
J)
MIC
Microphone connection (microphone located in the lower panel profile)
K)
Amplifier version
2A@30Vdc
(maximum 500mA for 100 seconds).
See ENCODING at the end of SECTION I: Installation Manual.
(door-opener connection).
"open door"
Pag 9

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Cityline duox 1lCityline duox 2l

Tabla de contenido