Attention; Placing In Operation; Error Indications On The Display; Power- On Routines - Weller WHP 200 Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13
We thank for the confidence you have shown by purchasing
the Weller Heating Plate WHP 200. During manufacture the
strictest quality requirements are applied; these assure the
correct function of the device and make it possible to obtain
optimal soldering results.

1. Attention!

Prior to placing the device in operation, please carefully read
these operating instructions and the safety instructions
enclosed. If the safety instructions are not observed, there is
a risk of injury.
The manufacturer accepts no liability for usage other than
that described in the operating instructions or for unautho-
rised modifications
The WELLER heating plate WHP 200 complies with the
EU declaration of conformity as per the essential safety
requirements in the directives 2004/108/EU and
2006/95/EU.
2. Description
The WHP 200 heating plate is equipped with a 200 W
infrared high-temperature lamp and enables the user to pre-
heat electronic assemblies in numerous ways. The high-
temperature lamp supplies energy primarily in the wave-
length range of 2 - 10 μm and heats modern tools quickly
and efficiently. Digital regulation electronics ensure precise
temperature behaviour.
Technical data
Dimensions:
165 x 195 x 70 mm
(W x L x H)
6,5 x 7,68 x 2,75 inch
Mains voltage:
230 V (120 V); 50 Hz (60 Hz)
Power:
Heating zone 200 W
Temperature range:
50°C - 400°C (150°F - 750°F)
Protection class:
1
Heating zone:
120 (4,72) x 60 (2,36) mm (inch)

3. Placing in operation

Remove all temperature sensitive and flammable objects
from the vicinity of the heating plate. Ensure that the heating
plate is switched off. Ensure that the mains voltage is cor-
rect. Connect the device to the mains (6). Switch on the
device at the mains switch (3). When the device is switched
on, a self-test is performed during which all display ele-
ments (1) are operated. The temperature set (setpoint) and
the temperature scale (°C / °F) are then displayed briefly.
The display then switches automatically to the indication of
the actual value. The red dot on the display illuminates (5).
This dot is a visual indication of the state of the regulation.
Continuous illumination indicates the system is warming up.
Flashing indicates that the operating temperature has been
reached.
3.1. Adjusting temperature
The digital display (1) normally indicates the actual temper-
ature. The digital display (1) switches to the current setpoint
when the "UP" or "DOWN" button (2)(4) is pressed. The set-
point (flashing indication) can now be changed as required
by pressing or pressing and holding the "UP" or "DOWN"
button (2)(4). If the button is pressed and held down, the set-
point changes quickly. Approx. 2 sec. after the button is
released, the digital display (1) automatically switches back
to the actual value.
3.2. Manual heating shut down (OFF)
The device heating is shut down by simultaneously pressing
the "UP" and "DOWN" buttons. "Off" appears on the display
(1).

4. Error indications on the display (1)

- - -
No temperature sensor detected
E10
Maximum housing temperature exceeded
5. Power-on routine
°C / °F change over
For this purpose the device is first switched off at the mains
switch (3). Press DOWN button (4) and switch on the device.
Keep button pressed until the "°F" appears on the dis-
play (1). When the "DOWN" button is released the setting is
saved. Use the same procedure for the change over to "°C".

6. PCB holder

The PCB holder is secured to the housing upper section by
the Heizone. For securing, removing or adjusting the PCB
holder, release the knurled screws.

7. Items supplied

WHP 200 heating plate
Mains cable
PCB holder
Operating instructions
Safety information
Subject to technical change without notice!
See the updated operating instructions at
www.weller-tools.com.
English
5

Publicidad

Tabla de contenido
loading

Tabla de contenido