Magnetostrictive Linear Position Sensor – Rod Style
6
Calibration procedure
Output
BTL
gradient
Rising
BTL7-A...
BTL7-G...
BTL7-C...
BTL7-E...
Falling
BTL7-A...
BTL7-G...
BTL7-C...
BTL7-E...
Tab. 6-1:
Value table for teach-in and inverting
6.1

Programming inputs

Programming inputs La and Lb must be used in order
to make settings. A programming input at 10 to 30 V
corresponds to activation (high active).
The Balluff BTL7-A-CB02-... adjusting box can be used
for this (see Accessories on page 22).
Automatic deactivation!
If no signals are transmitted via the programming
inputs for approx. 10 min, programming mode is
automatically ended.
6.2

Calibration procedure notes

Prerequisites
Programming inputs are connected.
The BTL is connected to the system controller.
Voltage or current values from the BTL can be read
(using a multimeter, the system control or the adjusting
box).
Fig. 6-1:
Connecting the BTL7-A-CB02-S... adjusting box
www.balluff.com
Unit
Min.
Null
value
value
V
−0.5
0
V
−10.5
−10.0
mA
0
0
mA
3.6
4.0
V
+10.5
+10.0
V
+10.5
+10.0
mA
20.4
20.0
mA
20.4
20.0
BTL
Adapter cable with
connector (socket)
Indication
Indication
for
for teach-in
adjustment
2.0
4.0
2.0
4.0
6.0
12.0
6.0
12.0
2.0
4.0
2.0
4.0
6.0
12.0
6.0
12.0
Values for null and end point
Any desired position of the magnet can be used as the
null or end point. However, the null and end points may
not be reversed.
The absolute null and end points must lie within the
minimum or maximum range of what can be output
(see value table).
The last set values are always saved, regardless
of whether the setting was ended using the
programming inputs or automatically after
10 min have expired.
Value table for teach-in and inverting
The following examples refer to BTL with 0 to
10 V or 4 to 20 mA output.
Calibration box
8-pin
End
Max.
Error
value
value
value
+10.0
+10.5
+10.5
+10.0
+10.5
+10.5
20.0
20.4
20.4
20.0
20.4
3.6
0
−0.5
−0.5
−10.0
−10.5
−10.5
0
0
20.4
4.0
3.6
3.6
Supply
6-pin