Performance Data List - Lotus 14005R4 Manual De Uso

Sistema de tratamiento del agua
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The lotus® Water Treatment System reduces contaminants and impurities*
The carbon-block filter captures Mercury, Lead and Chlorine. What the carbon-block filter does leave behind are those
desirable, naturally occurring minerals, such as magnesium, potassium and calcium that give drinking water it's great
taste. The carbon-block filter lasts about a year (approx. 365 gallons/1,400 liters).(**)(*)
lotus® Water Treatment System model LWT100/LWT100K with filter LWTRF1/LWTRF1K.
This system has been tested and certified by NSF International against NSF/ANSI Standards 42 and 53 for the
reduction of contaminants specified on this performance data sheet. The concentration of the indicated substances in
water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving
the system as specified in NSF/ANSI 42 and 53system as specified in NSF/ANSI 42 and 53
Contaminant
Influent
Water Avg.
Standard 42
Chlorine Taste
1.9mg/L
and Odor
5,200,000
Particulate Class
count/mL
l particles 0.5 to
1 microgram
Standard 53
58,000
Cyst*
cysts/L
(Cryptosporidium
,Giardia)
140 ug/L
Lead 6.5 pH
160 ug/L
Lead 8.5 pH
0.006 mg/L
Mercury 6.5 pH
0.0057 mg/L
Mercury 8.5 pH
16 ug/L
MTBE
210 ug/L
2,4-D
Test Parameters include:
• Temperature: 20°C +- 2.5°C
• pH: 7.5 +- 0.5 (unless noted otherwise)
• Flow rate: 0.42 GPM
• Max working pressure: maximum 20 PSI
• Rated service flow: Max. of approx. 10 liters of water per day
• Rated service life: 365 gallons/ 1,400 liters
* Do not use (this carbon-block filter alone) with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the (carbon-block filter) system. Systems Certification for Cyst Reduction may
be used on disinfected waters that may contain filterable Cysts.
** Filter tested under standard laboratory conditions; filter life may vary depending on local water conditions. Tested
and verified by independent laboratory testing for the bacterial and Protozoa claims on the Performance data list on
page 16. NSF Certification for a microbiological claim is for Cyst Reduction only.
While testing was performed under standard laboratory conditions, actual performance may vary.
This system is equipped with a performance indication device. When the carbon-block filter nears the end of its life cycle,
the status indicator light on the control panel will begin to flash amber. There are two warnings that are displayed on the
control panel: Slow-flashing amber light; There are about one hundred processing cycles (or less) left on the carbon-block
filter, Fast-flashing amber light; There are about 50 processing cycles (or less) left on the carbon-block filter. When the
amber light is on continuously, the system will not process any more water until the filter has been replaced.
3-23 Hannover Drive, Ontario, Canada, L2W 1A3, 1-800-808-1724, www.tersano.com

PERFORMANCE DATA LIST

Influent
Max.
Challenge
Permissible
Concentration
Product
mg/L
Water Conc.
2.0 mg/L
50% Red'n
+/- 10%
at least
85% Red'n
10,000
particles/mL
minimum
99.95%
50,000/L
Red'n
0.15 +/- 10%
10 ug/L
0.15 +/- 10%
10 ug/L
0.006 +/- 10%
0.002 mg/L
0.006 +/- 10%
0.005 mg/L
0.015 +/- 20%
5.0 ug/L
0.210 +/- 10%
70 ug/L
Tersano Inc.
Avg
Max.
0.05
0.09 mg/L
76,000
200,000
count/mL
count/mL
1 cysts/L
10 cysts/L
2 ug/L
6 ug/L
1 ug/L
5 ug/L
0.0002 mg/L
0.0002 mg/L
0.0002 mg/L
0.0002 mg/L
0.6 ug/L
2.0 ug/L
0.4 ug/L
2.6 ug/L
General information:
• Operating temperatures: Max. 30°C/86°F ; Min 2°C/36°F
• Electrical requirements: 120 Volts
• FL: Fibers per liter
• Red'n: Reduction
• Conc: Concentration
15
Avg.
Max
U.S. EPA
Max
Contaminati
on level
98.7%
97.9%
N/A
99.9%
99.9%
N/A
99.99%
99.99% N/A
98.6%
99.9%
10 ug/L
99.4%
99.4%
10 ug/L
96.7%
96.9%
0.002 mg/L
96.4%
96.5%
.002 mg/L
87.5%
96.8%
5.0 ug/L
98.8%
99.9%
70 ug/L