Programming
To view the service history log proceed as follows:
➤ Turn off the AC power.
➤ Press the Fan Button and hold it.
➤ Turn on the AC power.
➤ Once Power On Reset is completed (display indicates "888" and all LEDs
are lit) release the Fan Button.
✓ The display will flash the most recent fault detected, followed by the event
chronology number.
➤ To view other events detected press either the Up or Down Button.
➤ To clear the service history log simultaneously press the Power and Down
Buttons.
➤ To exit the service history log
– press either the Power, the Up or the Down Buttons or
– wait thirty seconds without pressing any button.
8
Programming
8.1
Entering Program Mode
➤ Press and hold the Power Button while in the Off Mode until the letter "P"
appears in the display.
✓ The characters "P1" followed by the parameter setting, appear in the
display.
✓ The Marine Climate System is now in the Program Mode.
NOTE
I
The Marine Climate System will exit the Program Mode and return
to the Off Mode if no programming is attempted for one minute.
8.2
Changing Program Parameters
➤ Increment from one program parameter to the next by pressing the Fan
Button.
➤ Press the Up and Down Buttons to select the data or set the desired limits
for the parameter being programmed.
14
MCS6, MCS12, MCS16
EN