Connecting the MSI412 and MSI424
Make sure that a professional fuse is installed between the positive pole (+)
and the inverter. Mind the following values:
MSI412: 50 A
MSI424: 25 A
A
NOTICE!
If no sufficient, professional fuse is installed, the inverter could
be damaged and the gaurantee is invalidated.
Do not reverse the polarity. Reversing the polarity of the con-
nections will cause a great spark and the internal fuses will
melt. These fuses should only be replaced by a qualified elec-
trician.
➤ To set up the inverter, connect the red cable to the positive pole (+) of the
vehicle battery and the black cable to the negative pole (–) of the vehicle
battery.
Make sure the vehicle battery terminals are clean when connecting them.
Connecting the external switch contact to the inverter
➤ Connect the external switch to the remote port according to the wiring dia-
gram (fig. 4, page 5).
➤ Put the switch (fig. 1 1, page 3) in position "I".
✓ The green status LED lights up (fig. 1 2, page 3) when the switch is
closed.
EN
Connecting the inverter