Miscellaneous - Medisana AH 661 Instrucciones De Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 47
3.6
Device will not switch on (LED not illuminating):
Faults
Plug in the plug; Check power circuit, socket and fuse.
and
No mist: Fill water tank.
Fault
No mist although tank full: Close the lid properly
Remedy-
Mist intensity too weak:
ing
Too much residue in the water canister, clean the ultrasonic trans-
ducer/water too dirty, replace.
White deposits:
Use clean water or at least 1/2 distilled water / 1/2 fresh tap water.
Unusual smell:
Polluted or stagnant water, clean the tank and fill up with fresh water.
Unusual noise:
Insufficient water in the tank, fill up with water/device is not on a solid
surface, place on a stable and level surface.
If a fault cannot be remedied using the described method, please contact
your service centre.

4 Miscellaneous

4.1
During everyday use it is advisable to give the device a thorough clean-
Clean-
ing at least every three days. Also clean device before and after long
ing and
storage periods.
mainte-
Before cleaning the device, make sure that it is turned off and the mains
nance
plug is removed from the socket.
Remove the water tank from the device and empty it.
Clean the outside of the unit with a soft, damp cloth.
Please do not use any aggressive substances for cleaning, such as
scouring cream or other detergents, as these may damage the sur-
faces and reduce the atomisation effect.
You can rinse out the water tank with hot water (>65 °C) or an alcohol
of at least 75 % vol. The atomiser chamber should be cleaned using an
alcoholsoaked cloth and cotton bud. Take care to ensure that no water
gets inside the humidifier.
The ultrasound generator is the most sensitive component in the de-
vice. It is important for it to be kept clean and handled with care. Use
e.g. a cleaning brush to remove all the residue and dirt particles. Never
clean the ultrasound generator using metal objects.
If you do not intend to use the unit for an extended period of time,
empty any remaining water from the tank and dry off the unit.
Store the unit in a cool, dry place, preferably in its original packaging.
Remove cap from underside of the water tank and store separately to
prevent sleeve gasket from sticking.