Terminal Arrangement; Installation; Mechanical Dimensions And Panel Cutout - LOVATO ELECTRIC DCRG8 Manual Operativo

Ocultar thumbs Ver también para DCRG8:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TERMINAL ARRANGEMENT

INSTALLATION

– DCRG8 is designed for flush-mount installation. With proper mounting, it guarantees IP54 front protection degree.
– Insert the controller into the panel cutout, making sure the gasket is properly positioned between the panel surface and the controller front frame.
– Make sure the tab of the customising label does not get folded under the gasket and impair the seal gripping. It should be positioned inside the panel.
– From inside the panel, for each of the four fixing clips (standard supplied with the controller in plastic bag), position the clip in the appropriate square hole
on the controller housing side, then move it backwards in order to insert its hook in place.
– Repeat the same operation for all four clips.
– Tighten the fixing screw with a maximum torque of 0.5Nm.
– In case the device needs to be removed, loosen the four clip screws and repeat the steps in reverse order.
– For the electrical connections, see the wiring diagrams in the dedicated chapter and the requirements given in the technical characteristics table.
MECHANICAL DIMENSIONS AND FRONT PANEL CUTOUT [mm]
144
1
4
5
6
7
8
10
11
2
3
9
I1
I2
I3 C
L1
L2
L3
N
nc
A1
A2
CURRENT INPUT
VOLTAGE INPUT
AUX SUPPLY
Ie = 1/5A~
100-600V~
100-415V~
110-250V=
600V~
50 / 60 Hz
12
13
14
15
16
17
18
19
20
21
22
43.3
10
35
73
G
B
138
29

Publicidad

Tabla de contenido
loading

Tabla de contenido