Once set the system date/time, proceed similarly to adjust your "Time
Zone" and "DST" settings for the automatic time change depending on
time of year.
Press "OK" to return to the main application.
To transfer the DATE/TIME parameters introduced in the touchscreen
to the system's CPU, press the validation DATE/TIME key in the
application main screen.
Warning
The other screen settings are set at factory default and should not be modified without the
supervision of an authorized Astralpool technician.
5.4. System initialization
RUN
Press this key to switch on the UV lamp.
WARNING:
In the event of a sudden disconnection of the lamp for any reason (stop, alarm, etc.), the system will not start the lamp
immediately but it will make a controlled re-ignition once the normal operating conditions are restored, thereby preserving its
integrity.
The re-ignition indicator will flash on the bottom of the screen.
Once started the lamp, this icon will appear at the bottom right of the screen.
Gradually, the system will adjust the output power level to reach the setpoint radiation depending on the model installed.
STOP
Press this key to switch off the UV lamp.
5.5. Alarm management
LOW FLOW
Whenever the installed sensor detects an insufficient water flow inside the UV reactor, the system
disconnects the UV lamp and the "Flow" indication of the screen will flash.
WARNING:
Once restored the water flow, the system automatically resets.
LOW RADIATION
Whenever the radiation sensor installed in the reactor detects too low values to ensure a dose of 60
2
mJ/cm
, even with the lamp running at 100% of its rated power, the system disconnects the UV lamp
and the "Radiation" indication of the screen will flash.
WARNING:
To prevent this situation from occurring prematurely, should action regularly the manual cleaning
device of the quartz sleeve.
16