Technical Data; Functional Description; Commissioning - Festool SYSLITE KAL II Manual De Instrucciones

Ocultar thumbs Ver también para SYSLITE KAL II:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4

Technical data

Compact working light
Rated voltage / capacity of integral battery (LiIon)
Rated voltage with external Festool battery pack
Charging socket voltage range
Lighting device
Light duration (internal bat-
tery)
Luminous flux, brightness
Charge time of internal battery 90% / 100%
Permitted operating temperature range
Permitted battery temperature for charging
Weight (without external battery pack)
Protection type
5

Functional description

The pictures for the functional descrip-
tion are on a fold-out page at the begin-
ning of the instruction manual. While
reading the manual you can fold out the
page for comparison and quick refer-
ence.
[1-1] Charging state indicator LED
[1-2] On/off switch with 3 settings
[1-3] Folding attachment handle
[1-4] Connecting socket for charging
adapter
Min. light: Stage 1 (30%)
Max. light: Stage 2 (100%)
Min. light: Stage 1 (30%)
Max. light: Stage 2 (100%)
[1-5] Magnetic foot with spherical head*
[1-6] Adapter plate*
[1-7] Mains charging adapter*
[1-8] Vehicle charging adapter
* not on all versions included in the
scope of delivery
6
6.1
Prior to initial operation: charge
battery pack for approx. 4 h!
-
12x 1.5W Power LED
2 h 40 min / 3 h 20 min.

Commissioning

Charging the integral battery
pack
KAL II
7,2 V = / 2,9 Ah
10,8 - 19V =
+
7,2 - 19 V =
5 h 30 min.
2 h 10 min.
310 Lumen
769 Lumen
-5 °C to +55 °C
0 °C to +45 °C
0,7 kg
IP 2X
5

Publicidad

Tabla de contenido
loading

Tabla de contenido