Cleaning The Hygienic Exhaust Filter; Spare Parts And Accessories; Recommendation; Before You Send In The Appliance - Dirt Devil Vito Plus Manual De Instrucciones

Aspiradora rodante con bolsa
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 28
5 Maintenance

5.3 Cleaning the hygienic exhaust filter

13
14

5.4 Spare parts and accessories

ATTENTION:
Only use original spare parts from the scope of delivery or those that you
have acquired by reordering.
Ordering address:
page 48, „International Service"
Further information is available at:

5.5 Recommendation

We recommend:
>> Swirl Y12 dust filter bags with MicroPor filtration <<

5.6 Before you send in the appliance

WARNING:
Danger of injury! Never use a defective appliance! Always switch off the
appliance and disconnect it from the mains before starting troubleshoot-
ing
chapter 4.3, „Switching off".
Before contacting your authorised Royal dealer, Royal service partner or
appliance market or sending in the appliance, first follow the procedure in
the following table to check if you can solve the problem yourself.
Problem
Filter bag
The dust filter bag is full.
change indicator
Change the dust filter bag
appears in the
the dust filter bag".
display window.
Nozzle, telescopic tube or suction hose are blocked.
Remove the obstacle. If necessary, use a long wooden
stick (e.g. a broomstick) to do this.
The filters are dirty.
Clean the respective filter
motor protection filter" or
hygienic exhaust filter".
The vacuum
The overheating protection has tripped (possibly due
cleaner stops
to blocked suction channels, filters, or similar). Switch
suddenly.
the appliance off and pull the plug out of the socket.
Remove the cause of overheating (e.g. by disassem-
bling telescopic tube and suction hose and removing
the obstacle and/or cleaning filters). Wait for about
45 minutes. After the appliance has cooled off, you
may switch it on again.
A B
A B
www.dirtdevil.de
Possible cause / solution
chapter 5.1, „Changing
chapter 5.2, „Cleaning the
chapter 5.3, „Cleaning the
1. Switch off the appliance,
chapter 4.3, „Switching off".
2. Push the release catch of the exhaust filter cover (Fig. 13/A) and lift off
the exhaust filter cover.
3. Pull the hygienic exhaust filter up out of its holder (Fig. 13/B) and tap
the dirt from it over a dust bin.
4. Should this be insufficient, remove the dirt from the filter with a soft
brush, e.g. the furniture brush supplied with the appliance (Fig. 14/A).
5. If such dry cleaning is insufficient, thoroughly rinse the filter by hand in
running clear cold or hand-warm water.
ATTENTION:
The filters are washable, but not suitable for cleaning in washing
machines or dishwashers. Do not use chemical cleansers to clean the
filter. Leave the filters to dry after cleaning them with water
(approx. 24 hours at room temperature). Only put them back into the
appliance when they are completely dry.
6. If the filter is damaged or deformed, replace it (ordering information
chapter 5.4, „Spare parts and accessories").
7. Place the clean/new hygienic exhaust filter back into its fitting (Fig. 13/
B).
8. Then fit the exhaust filter cover on the rear side first and then push it
down on the front side (Fig. 14/B).
Item number
7075022
Set of 5 dust filter bags and 1 motor protection filter
7075002
1 hygienic exhaust filter
M232
1 long flexible crevice nozzle
M203-4
1 parquet brush
M208-8
1 turbo brush
®
®
Swirl
, MicroPor
and "Y12" are registered trademarks of a company of
the Melitta Group and are used with their permission.
Problem
The cleaning re-
The bypass vent (Fig. 1/15) is open.
sults are unsat-
Close the bypass vent (Fig. 1/15).
isfactory in spite
The attached nozzle is unsuitable. Change the nozzle,
of the appliance
chapter 3.2, „Selecting the proper nozzle"
working correct-
Position of the suction power control (Fig. 1/17) is not
ly.
suitable for the floor. Adjust the suction power control
(Fig. 1/17),
The position of the "carpet/hard floor" selector (Fig. 1/
2) is unsuitable for the floor. Set the "carpet/hard floor"
selector (Fig. 1/2) to the correct position,
4.2, „Vacuum cleaning", step 5.
The dust filter bag is full. Change the dust filter bag
chapter 5.1, „Changing the dust filter bag".
The filters are dirty. Clean the respective filter
chapter 5.2, „Cleaning the motor protection filter" or
chapter 5.3, „Cleaning the hygienic exhaust filter".
Nozzle, telescopic tube or suction hose are blocked.
Remove the obstacle. If necessary, use a long wooden
stick (e.g. a broomstick) to do this.
Dust compart-
Dust filter bag has not been inserted or has been in-
ment cover can-
serted incorrectly. Insert the dust filter bag correctly,
not be closed
chapter 5.1, „Changing the dust filter bag".
NOTE:
If you cannot solve the problem following these instructions, contact the
Royal Appliance customer service ( page 48, „International Service").
Description
Possible cause / solution
chapter 4.2, „Vacuum cleaning", step 4.
chapter
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

M2012-2

Tabla de contenido