3.1
Preparing
for
Clean and disinfect the nebulizer kit as described under "4.1
inhalation
Cleaning and maintenance" in order to avoid a possible infection
by contaminated parts!
Additionally general hygiene regulations (e.g. thoroughly washing
the hands, hygienic handling of the medication) must be observed.
1.
2.
r
g
/
:
3.
h
:
4.
5a.
5b.
WARNING
NOTE
Before starting therapy, discuss the length, dosage and frequency
of use with your doctor. The method of use should be appropriate
to the aim of the therapy (e.g. lung treatment = use of mouthpiece
and treatment of the nasal-pharyngeal area = use of mask).
Consult your doctor about this aspect as well.
Rotate the inhalation top
w
nebulizer tank
.
Place the vaporizer head
NOTE
The are two additional vaporizer heads included in the scope of
delivery of model IN 550 Pro (art.no. 54530). You have the possi-
bility to use one of totally 3 heads (blue
e
the nozzle
. This allows a more targeted application. Particle
sizes of approx. 4.5 to 6.0 µm (red vaporizer head) are ideal for use
on mouth and throat (e.g. laryngitis). Particle sizes of approx. 3.5
to 4.5 µm (blue vaporizer head) are ideal for use on the respiratory
tract and upper lungs (e.g. bronchitis) and smaller particle sizes of
approx. 3.0 to 4.0 µm (yellow vaporizer head) are ideal for the
deeper areas of the lung (e.g. asthma). Consult your physician
to find out, which particle size is ideal for your personal situation.
Fill in the correct amount (min. 2 ml and max. 10 ml) of prescribed
medication into the nebulizer tank
pour all the liquid out and clean the nebulizer kit as described
under point "4.1 Cleaning and maintenance".
Rotate the inhalation top
w
tank
.
Plug either the mouthpiece
connection tube for mouthpiece and nose adaptor
top. Therefore the connection tube
on the upper part of the inhalation top with the longer end. Then the
s
mouthpiece
or the nose adaptor (
to the shorter end of the connection tube
Alternatively, you may use the adult or child mask (
inhalation. Therefore you need the mask connection tube instead of the
connection tube
Connect the power plug to the mains outlet and place one end of the
u
air tube
firmly over the connection for air tube
sor. Place the other end over the appropriate connection for air tube
of the nebulizer kit.
t
counterclockwise to remove it from the
r
on the nozzle
w
t
clockwise to properly fix it on the nebulizer
s
, or a nose adaptor (
z
z
. Make sure, the power switch
3 Operating
e
.
r
g
, red
or yellow
. If you have overfilled the tank
p
or
z
onto the inhalation
needs to be put onto the nozzle
p
a
or
) needs to be connected
z
.
i
3
is turned off ("O").
1
of the compres-
GB
g
h
) on
g
g
a
) with the
g
o
or
) for the
q
f
19