English
-
You will have warning in home menu
tions. These errors should desappiers in 10 minutes maximum. If
not, check devices which are still in rf errors, put them in another
place and repeat the procedure.
14. Hydraulic systems
If your installation has hydraulic elements, you may have to drive
pumps or boilers. With My Way you can drive directly up to 4 hydrau-
lic circuits. And for each of those circuits, an RF remote device can
be linked. It works easily: if at least one element of the circuit has a
heating demand, the element will drive the circuit and make the water
flows.
First step: define on which circuit an element belongs to.
With the plan of your installation, define which elements are on "circuit
1". Once it is done, on My Way, configure all elements (heating/cooling
device) that are on circuit 1.
To do this, in the main screen press
then press
, and select one device of circuit 1 and press
onds. Now you have entered the configuration menu of the device.
Choose menu "HC", now you have two option Electrical or Hydraulic,
select Hyraulic and then press on button
circuit, that the device will act on.
Proceed like this for every heating/cooling device of this circuit.
Once all elements of circuit 1 are set, do the same for the other hydraulic
circuits.
Second step: control the circuits.
For each circuit, you can link an element to drive the pump/boiler of the
circuit. This can be done for example by Generator Controller.
From the main screen, press
"Radio pairing", then "Circuit". Select the number of the circuit, put the
element to link in link mode, then start process by pressing
Do the same for the other circuit, if you have more.
15. Away/Home management
From the home screen, user can quickly switch from away
-
Away. All heating devices are switched in ECO mode, all ON/OFF
devices and electrical radiators are switched in OFF mode
-
HOME. All devices back to the previous status before Away
16. Day/night configuration
The Day/Night function works like a whole installation command. To use
it, user needs to set each device as Day or Night device trough the device
settings. From home menu:
1 2
→
→
3 4
long press on
And to manage devices, user can do it through home menu:
for rf errors communica-
1 2
, enter a zone that is on circuit 1,
3 4
. Now you can select the
then press
. On the list box, choose
.
/
Zone: DAY
→
→
17. Example of installation
Room 1
Master
and/or
In this configuration:
•
Pair first the thermostat (master) with the Central before pairing the
other devices.
•
The actuators regulate on thermostat temperature.
During the pairing, the Central create automatically rooms
5 sec-
according to the number of thermostats (rooms) of UFHs.
Default names are given to the rooms. You can modify
them in the menu "House creation" (you can identify these
rooms with different setting temperatures)
18. Remote control
Connect the central unit to WiFi: See WiFi setting above.
Make sure that the central is connected to the WiFi network with an IP
address (See WiFi status , chapter WiFi setting ) otherwise you need to
connect the central unit to WiFi.
You are allowed to control the central unit whether by PC, link to the WEB
page (www.cordivari.it), or download Cordivari My Way application from
App store or Google Play on your Smart Phone.
1)
Connect to the web pages to drive your central unit, download the
APP.
2)
Create an account.
3)
Validate your email.
home.
4)
Request a pairing code to link your central unit to your account. The
pairing code (valid 24h) is sent to your mail box.
5)
In the WiFi status menu
code.
Your central unit should appear after a few minutes in the application
or the web page. It may take up to a few hours to display all rooms
and devices in the application. You can then drive your central unit from
everywhere.
Cordivari is not responsible for the correct operation of the connected
devices, and potential damage caused by malfunction or improper use of
the connected devices and appliances.
19. Remarks
When a modification of the setting is performed on the central unit, the
synchronization with devices using batteries can take up to 7mn in order
to save batteries.
- 18 -
and/or
of the central unit, enter the pairing
Cod. 1910000000259 - nv00