PRODUCT DATA SHEETS
Base Grille Water
Filtration
System
Model WF-L200V Capacity 200 Gallons (757 Liters)
Model WF-NL120V Capacity 120 Gallons (454 Liters)
System tested and certified by NSF International against NSF/ANSi
Standard 53 for the reduction of Lead, Mercury, Benzene,
p-dichlorobenzene,
O-Dichlorobenzene,
Toxaphene, Ethyl Benzene,
1,2,4-tricMorobenzene
and against NSF/ANSI Standard 42 for the
reduction of Chlorine Taste and Odor and Particulate Class Ill=
This system has been tested according to ANSl/NSF 42/53 for the reduction of the substances
listed below. The concentration
of
the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissible limit for
water
leaving
the system,
as specified
in ANSI/NSF
42/53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
_>50%
1.9 mg/L
2.0 mg/L _+10%
0.07 mg/L
0.06 mg/L
>75%
>75%
49333/mL
312/mL
98.7%
99.0%
Part cu ate C ass
*
_>85%
At east 10,000 par_ c es/mL 640/mL**
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead:@ pH 6.5
0.Olmg/L
0.14 mg/L _
0.15 mg/L _+10%
0.0014 mg/L
0.0011 mg/L
99.00%
99.21%
Lead: @ pH 8.5
0.01 mg/L
0.15 mg/L t
0.15 mg/L
_+10%
0.0069 mg/L
0.0042 mg/L
95.40%%
97.20%
Mercury: @ pH 6.5
0.002 mg/L
0.0059 mg/L
0.006 mg/L _+10%
0.0009 mg/L
0.0004 mg/L
84.74%
93.22%
Mercury: @ pH 8.5
0.002 mg/L
0.0054 mg/L
0.006 mg/L
_+10%
0.0007mg/L
0.00043 mg/L
87.03%
92.03%
Benzene
0.005 mg/L
0.0157 mg/L
0.015 mg/L _+10%
0.002 mg/L
0.00083 mg/L
87.26%
94.71%
p-dichlorobenzene
0.075 mg/L
0.210 mg/L
0.225 mg/L _+10%
0.0005 mg/L
0.0005 mg/L
99.76%
99.76%
O-Dichlorobenzene
0.60
1.84
1.8 _+10%
0.20
0.0418
89.13
97.73
Toxaphene
0.003
0.0143
0.015 _+10%
0.0012
0.0010
91.60
93.00
Ethyl Benzene
0.70
2.00
2.1 _+10%
0.40
0.085
80.00
95.75
1,2,4- trichlorobenzene
0.07
0.232
0.21 _+10%
0.0041
0.0016
98.23
99.31
Test Parameters: pH = 7.5 + 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).
•
It is essential that operational, maintenance,
and filter
replacement requirements be carried out for the product to
perform as advertised.
•
Model WF-L2OOV: The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended
that you
replace the filter. Use replacement cartridge L200V/NL120V,
part #4396701. 2005 suggested retail price of $32.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
Model WF-NL120V: Change the water filter cartridge every 6-
9 months. Use replacement cartridge L200V/NL120V,
part
#4396701. 2005 suggested retail price of $32.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
•
The product is for cold water use only.
•
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection
before or after
the system.
•
Refer to the front cover or "Accessories"
section for the
Manufacturer's
name, address and telephone number.
•
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Application Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate
0.5 GPM (1.9 L/min.) @ 60 psi.
*Class III particle size: > 5 to < 15 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
tThese contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
® NSF is a registered trademark
of NSF International.
17