Base Grille Water
Filtration
System
Model WF-NLC120V Capacity 120 Gallons (454 Liters)
System tested and certified by NSF International against NSF/ANSi
Standard 53 for the reduction of Lead, Mercury, Benzene,
p-dichlorobenzene,
Cysts, Turbidity, Asbestos, Endrin,
O-DicNorobenzene,
Toxaphene, Ethyl Benzene, 1,2,4-trichlorobenzene
and against NSF/ANSI Standard 42 for the reduction of Chlorine Taste
and Odor and Particulate Class I=
This system has been tested according to ANSl/NSF 42/53 for the reduction of the substances
listed below. The concentration
of
the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
_>50%
1.9 mg/L
2.0 mg/L _+10%
0.12 mg/L
0.08 mg/L
>75%
>75%
50,000/mL**
15,725/mL
99.7%
Part cu ate C ass *
_>85%
5,300,000/mL
At east 10,000 par_ c es/mL
99.0%
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.Olmg/L
0.14 mg/L t
0.15 mg/L _+10%
0.001 mg/L
0.001 mg/L
99.29%
99.29%
Lead: @ pH 8.5
0.01 mg/L
0.15 mg/L r
0.15 mg/L
_+10%
0.001 mg/L
0.001 mg/L
99.32%
99.32%
Mercury: @ pH 6.5
0.002 mg/L
0.0058 mg/L
0.006 mg/L _+10%
0.0005 mg/L
0.0003 mg/L
91.37%
94.82%
Mercury: @ pH 8.5
0.002 mg/L
0.0055 mg/L
0.006 mg/L
_+10%
0.0013 mg/L
0.0005 mg/L
76.36%
90.90%
Benzene
0.005 mg/L
0.0153 mg/L
0.015 mg/L _+10%
0.0036 mg/L
0.0014 mg/L
76.47%
90.84%
p-dichlorobenzene
0.075 mg/L
0.215 mg/L
0.225 mg/L _+10%
0.0037 mg/L
0.0010 mg/L
98.27%
99.52%
Asbestos
99.0%**
842 x 107
107to 10_fibers/L rt
1.6 x 107 mg/L
1.6 x 107 mg/L
99.81
99.81%
Cysts _
99.95%
165,500/mL
50,000/L min.
1 mg/L
1 mg/L
99.99%
99.99%
Turbidity
0.5 NTU
11.75 NTU
11 _+1 NTU
0.38 NTU
0.22 NTU
96.76%
98.12%
Endrin
0.002
0.0056
0.006 _+10%
0.0007
0.0004
87.50
92.85
O-Dichlorobenzene
0.60
1.84
1.8 _+10%
0.33
0.071
82.06
96.14
Toxaphene
0.003
0.0143
0.015 _+10%
0.001
0.001
93.00
93.00
Ethyl Benzene
0.70
2.00
2.1 _+10%
0.60
0.169
70.00
91.55
1,2,4- trichlorobenzene
0.07
0.232
0.21 _+10%
0.0025
0.0007
98.92
99.69
Test Parameters: pH = 7.5 + 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure =
(17.2°C).
•
It is essential that operational, maintenance,
and filter
replacement requirements be carried out for the product to
perform as advertised.
•
Model WF-NLC120V:
Change the water filter cartridge every
6-9 months. Use replacement cartridge NLC120'7, part
#4396701. 2005 suggested retail price of $32.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
•
The product is for cold water use only.
•
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection
before or after
the system. Systems certified for cyst reduction may be used
on disinfected
waters that may contain filterable cysts.
•
Refer to the front cover or "Accessories"
section for the
Manufacturer's
name, address and telephone number.
•
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
60 psig (413.7 kPa). Temp. = 63°F
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 GPM (1.89 L/min.)
@ 60 psi.
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
tThese contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
ttFibers greater than 10 um in length
_Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF International.
18