Connection From Behind - NuTone PUREPOWER Serie Manual De Instalación

Ocultar thumbs Ver también para PUREPOWER Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CI367 VACUSWEEP® INLET VALVE
INSTALLATION INSTRUCTIONS (

CONNECTION FROM BEHIND

 Choose a location under the cabinet for the CI367
VacuSweep inlet valve so that it can be connected
to the central vacuum tube. Measure distance (X)
between the kickplate face and the inside edge
of the cabinet. Then, add 2¾" to the measured
distance. Refer to figure . Measure out the new
distance (X + 2¾") from the cabinet door, to the
reference mark.
 Drill a small reference hole straight down through
to the basement. Refer to figure . Locate the
reference hole in the basement and verify that there
are no obstructions.
 Using a reciprocating saw, cut an access hole in the
floor under the cabinet and approximately 8" behind
the location of the VacuSweep inlet valve reference
hole so that the CI367 VacuSweep inlet valve can be
connected to vacuum tube by reaching through the
access hole. Refer to figure .
 Using the reference hole as a center, cut a
2 ³/
" H x 6
5
/
" W rough opening in the kickplate
8
8
face. Refer to figure .
 Insert a coupling (model no. CF388) onto the rear
of the housing. DO NOT GLUE this connection
(Designed for friction fit). Refer to figure . Make
the terminal connections to the CI367 VacuSweep
inlet valve by sliding the low-voltage wire into wire
clips. Turn the power to the vacuum unit ON to test
the connection. After successful completion of the
test, turn power to the vacuum unit OFF. Insert the
CI367 VacuSweep inlet valve into the cabinet base
and tube.
 With the door in an open position, secure the CI367
VacuSweep inlet valve to the cabinet base using
no. 6 screws. Refer to figure . Ensure that the
spring on the electrical connector has 1/8"
clearance to rough opening. From the basement
reach through the access hole and glue a section
of 2" central vacuum tube to the coupling. Continue
with remainder of central vacuum connections.
'
CONT
D
C
ABINET
(X) + (2¾")
DOOR
R
EFERENCE
C
ABINET
M
ARK
X
2¾"
K
ICKPLATE
S
UBFLOOR
J
OIST
C
8"
UT
ACCESS
8"
HOLE BEHIND
REFERENCE HOLE
2"
CENTRAL
VAC PIPE
C
OUPLING
D
O NOT GLUE
THIS CONNECTION
G
CI367
LUE THIS
CONNECTION
V
S
®
ACU
WEEP
(
COUPLING
I
NLET VALVE
AD0091A
22
)
R
EFERENCE
MARK
R
EFERENCE HOLE
SEEN FROM BASEMENT
J
OIST
C
ABINET
DOOR
R
EFERENCE
HOLE
C
J
OIST
ROUGH OPENING USING THE
REFERENCE HOLE AS CENTER
T
ERMINAL CONNECTIONS
CI367
G
V
S
®
ACU
WEEP
CONNECTION
I
NLET VALVE
2
. 6
X NO
/
)
PIPE
SCREWS
8"
D
O NOT GLUE
ACCESS
THIS CONNECTION
HOLE
C
ABINET
S
UBFLOOR
8"
ACCESS HOLE
5
23/
" H
6
/
" W
UT A
X
8
8
C
OUPLING
2"
CENTRAL
LUE THIS
VAC PIPE
T
ERMINAL
WIRES

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido