POWER UNIT INSTALLATION

CHANGING INTAKE LINE DIRECTION

The intake line connects to the right side of the unit. However,
it is possible to change this configuration; to connect the intake
line to the left side of the unit, follow these steps:
Remove debris pail from power unit by releasing both latches
on sides of the unit, pulling them out and then pushing up.
Detach the pail from unit.
PP500 only: Grasp
the edges of the bag
collar and pull down;
the bag will slide off
easily. Do not pull on
the bag. Set the bag
aside.
PP500 only: Using a
Phillips
screwdriver
no. 2, remove the
screw tightening the
bag
adapter
and
intake elbow junction.
Disassemble
the
bag adapter from the
intake elbow and set
aside with its screw
AD0075
and nut.
All units: Disassemble
the intake elbow from
the back of the unit
using a 3/8" socket
to remove its both
retaining
nuts
and
screws.
All units: Flip the
intake
elbow
180°,
then reassemble it to
the unit, taking care to
keep its gasket at its
original position.
NOTE: Ensure
the
AD0077
gasket is not folded in
order to prevent lack of suction and noise.
PP500 only: put the
bag adaptor back in
place to the intake
elbow. Align triangle
with
small
inclined
stud,
then
tighten
the
junction
using
the screw and nut
previously removed in
.
AD0078
PP500
ONLY
AO0078
PP500
ONLY
AD0076
PP500
ONLY
PP500 only: Put the
bag back in place by
grasping the edges of
its collar and insert
over bag adapter. Be
careful not to tear the
bag. Ensure the collar
is positioned between
the taper ring and the
bag stopper on the
bag adapter.
All units: Put the debris pail back in its place.
CONVERTING POWER UNIT FROM
CYCLONIC
OPERATION
BAGGED SYSTEM (DEBRIS BAG
INCLUDED)
Both PP600 and PP650 units are factory shipped ready for
use in cyclonic mode, but due to their hybrid design, they can
also be operated with a disposable bag (391). The bag adapter
(included with the unit) must be installed if the disposable bag
will be used. Follow these steps:
NOTE: Do not remove the cyclonic filter.
Remove the pail from unit by releasing its both side latches,
pulling them out and then pushing them up. Detach the pail
from unit.
Assemble
the
bag
adapter to the intake
elbow. Align triangle
with
small
inclined
stud.
Tighten the junction
using the screw and
nut (included in parts
bag).
Unfold the disposable bag and grasp its collar where
indicated. Insert over bag adapter. Be careful not to tear the
bag. Ensure the collar is positioned between the taper ring
and the bag stopper on the bag adapter (see illustration
below). Put the pail back in its place.
AO0085
27
PP500
ONLY
T
APER RING
B
AG STOPPER
AO0080
TO
AD0080
AD0081
T
APER RING
B
AG STOPPER
A

Publicidad