English
Switching the pump on/off
1. Inside the aquarium: Attach the device below water level at the bottom or the inside
of your aquarium (⌦F). Pay attention to the maximum pond depth (see Technical
data).
Outside the aquarium: Attach the device to a stable surface outside of your
aquarium (⌦G).
2. Insert the mains plug in the mains socket. Attention: The pump starts immedi-
ately!
3. To turn it off, remove the mains plug from the mains socket.
Controlling the flow rate
1. Turn the power controller to adjust the water flow rate (⌦H).
6. Maintenance
DANGER! Electrocution!
▶ All devices must be disconnected from the power supply before any maintenance
work is carried out.
CAUTION! Material damage.
▶ Do not use hard objects or aggressive cleaning agents for cleaning.
▶ The appliance components are not dishwasher-proof. Do not clean the appliance or
appliance parts in the dishwasher.
The following sections describe maintenance work necessary for optimum and fault-free
operation. Regular maintenance prolongs the service life and assures functionality of the
appliance over a long period.
Cleaning the pump
1. Remove the pump from the aquarium.
2. Loosen and remove the two lateral fastening screws a (⌦C).
3. Pull the pump cover b out of the engine body from the front.
4. Pull the impeller e out of the engine body (⌦I).
5. Clean all components under running water.
6. Install the pump again in reverse order.
21