EHEIM compactON 5000 Manual De Instrucciones página 19

Ocultar thumbs Ver también para compactON 5000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
English
▶ compactON 5000: Pay attention to the installation direction of the impeller. The lug g in the impeller cover must
engage in the recess h in the motor body.
▶ compactON 9000 / 12000: When assembling, make sure that the markings j on the impeller and on the motor hous-
ing align with each other.
7.
Clearing faults
DANGER! Electrocution!
▶ Before clearing faults, remove the mains plug.
Faults
Pump does not start
Pump turns off
Pump does not pump
Pump does not pump
Pump not pumping
sufficiently
For other faults, please contact EHEIM Service.
Possible cause
No mains voltage
The pump is provided with an electronic device
for rotation control and this is also able to evalua-
te the functioning conditions. If there is a lack of
water or the pump is blocked, the pump recogni-
ses the problem and stops. After 10 attempts to
start again, in the space of 1 minute, the pump
turns off completely.
Mains plug is not inserted
Impeller is blocked
Shortage of water
Thermal cut-out has activated
Filter basket is dirty
Remedy
▶ Check the mains
voltage
▶ Check the supply line
1. Remove the mains plug.
2. Remove the cause of the problem.
3. Reconnect the mains plug.
▶ Insert the mains plug in the mains socket
▶ Clean the pump
▶ Add more water.
1. Remove the mains plug and let the pump
cool down.
2. Insert the mains plug again after approx.
one hour.
▶ Clean the filter basket
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Compacton 9000Compacton 12000

Tabla de contenido