3.2. Polyester swimming pools.

a) Cutting the panel. (Fig. 3)
Place the template (15) on the interior part of the
swimming pool panel, such that the distance betwe-
en the plane XY and the maximum height of the
structure is 400 mm. The plane XY must be parallel
to the maximum-height plane of the swimming pool.
Mark the 14 assembly holes and cut along the dot-
ted-line zone of the template so as to mark the cut
outline on the panel.
Cut the outline and drill the holes marked in the
panel.
b) Pre-assembly, according to the drawing:
Clean the contact surfaces between the gaskets
(2), rear body (3) and counterflange (1) and the
panel of the swimming pool.
Stick a gasket (2) onto the counterflange (1). (Fig. A)
Stick a gasket (2) onto the rear body (3). (Fig. C)
Secure the counterflange (1) through the rear part
of the swimming pool panel, fit the rear body (3)
from the other side of the panel and hold it firmly in
place while the two screws (13) are driven into the
holes A and B. (Fig. D)
Ensure that the rear body (3) is in correct position.
The word "HAUT" must be at the top part. (Fig. E)
c) Assembly.
Stick the gasket (2) to the flange (5). (Fig. I)
Place the flange (5) on the rear body (3). Drive the
screws (11) fully home. Avoid excessive force when
driving home the screws. (Fig. F)
Withdraw the protective plate (4) and stow it safely.
(Fig. H)

3.3. Masonry swimming pools.

a) Preparatory work.
Place the section to be embedded (16) with its pro-
tective plate (17) fixed in the metal mesh which
acts as a framework for the concrete.
Put it in position, bearing in mind that there must be
a distance of approximately 400 mm between the
centre of the section to be embedded and the
maximum height of the swimming-pool.
Position the surfaces of the part in a perpendicular
manner at the base of the swimming-pool.
The surface of the section to be embedded (16),
indicated by the letter S in (Fig. J), must be aligned
with the surface of the concrete once it has been
sprayed, so that the front plate (6) is well placed
once the ceramic wall-tiles have been fixed in
place. (Fig. J)
Once the concrete has been sprayed, remove the
protecting plate (17) and clean the surface of the
embedded section (16).
Attach the foam gasket (2) to the embedded sec-
tion (16)
Introduce the front section (3) into the embedded
section (16) and join together with screws (18)
(Fig. K)
Ensure that the rear body (3) is in correct position.
The word "HAUT" must be at the top part. (Fig. E)

3.4. Fitting front plate.

Pass the capillary pipe (7) through the hole in the
rear body (3) until it emerges from the end of the
hose on the side of the connections to the pump.
(Fig. N)
Fit the capillary pipe (7) by pressing it into the pres-
sure switch and ensuring that it is securely con-
nected. Offer the front plate (6) up to the rear body
(3), ensuring that the rubber gasket is in place
before fixing the unit with the 3 M5 screws (12).
For sprayed concrete swimming-pools, place joints
no.(19) and/or (20) as necessary to adjust the jet of
the front plate (6).

3.5. Fitting the air hose

The hose must be attached to the wall to form an air
trap, or at a level above the maximum height of the
swimming pool, so as to avoid emptying the pool.
Alternatively, it can be attached to the wall at a height
between the waterline and the maximum height of
the pool. Use a securing staple (10) to ensure correct
fitting.
Mount the filter (9) on the end of the hose in order to
prevent dirt entering. (Fig. P)

3.6. Fitting the pressure switch.

The hose must be attached to the wall to form an air
trap, or at a level above the maximum height of the
swimming pool, so as to avoid emptying the pool. Use
a securing staple (10) to ensure correct fitting.
Cut the hose to the right length to reach the panel (8)
and mount the filter (9) on the end of the hose in order
to prevent dirt entering.
The maximum length to ensure correct operation of
the pressure switch is 25 metres. It is advisable to cut
the capillary pipe to just the right length to reach the
panel (8), ensuring that the connecting pipe is passed
through again. (Fig. Q)
Connect the capillary pipe (7) to the pressure switch,
ensuring that it is firmly connected. (Fig. R)

3.7. Fitting the pump.

Pump installation and assembly must be carried out
by an authorised installer.
a) General safety warnings.
The equipment must be fitted following
current safety regulations for installing swim-
ming pools, and particularly standard IEC
60364-7-702 and the special regulations for
each application.
The pump must be installed on a flat surface
and attached to the floor.
To ensure the safety of persons, the pump
must be installed at least 3.5 metres from
the swimming pool.