Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 14
Control Panel CP F
Operating instructions
Please be sure to read the instructions for installation
and use before attempting to connect and use this
device!
Symbols used
Symbol indicates a possible hazard.
Safety instructions
To protect you from electrical shocks, injury or burns
the following basic safety principles must be observed
when using electrical devices. Please read and follow these
instructions before using the device.
Installation
Ensure that the devices are positioned safely and cannot fall
down or over. Always position the cables to ensure they do
not pose a tripping hazard. Do not expose electrical devices to
rain. Do not operate electrical devices in damp or wet environ-
ments. Do not operate electrical devices close to flammable
liquids or gases. Position the devices so that they are out of
the reach of children.
Protection against an electrical shock
Only operate devices whose casings and cables are undam-
aged. Ensure the cables are installed safely. Do not pull on the
cables.
Use
Do not use electrical devices for purposes other than those
stated by the manufacturer.
Repairs
Do not repair or modify the device. Please contact your dealer
or the Truma Service (see service manual or www.truma.com).
Accessories
Only use accessories and additional devices that are supplied
or recommended by the manufacturer.
Application purpose
Switch panel with main switch and four thermally triggered
circuit breakers (overload safety switch) to protect 12 V con-
sumer circuits. The device is designed for use in caravans and
campers. The device is designed for installation in caravans,
campers and boats.
Function description
If there is an overload, the snap-action mechanism in the cir-
cuit breaker triggers and the safety button jumps out.
The circuit breaker can be switched on after a cool-down
phase by pressing the safety button again.
4
IV
I
II
III
1
Main switch for the power circuits I, II and III
= On
= Off
I
Power circuit I for consumers up to 10 A
II
Power circuit II for consumers up to 7 A
III
Power circuit III for consumers up to 7 A
IV Power circuit for refrigerator up to 12 A
Continuous current – this power circuit cannot be
switched via the main switch.
Maintenance
Clean the panel with a dry and fluff-free cloth.
Disposal
The device must be disposed of in line with the administrative
regulations of the respective land in which it is used.
National regulations and laws (in Germany, for example,
the Altfahrzeug-Verordnung [old vehicle directive]) must be
observed.

Technical Data

Operational voltage
Direct voltage 12 V
Main switch (max. load)
20 A
Power circuits (max. load)
I = 10 A
II = 7 A
III = 7 A
IV = 12 A (not via the main switch)
Ambient temperature
-20 °C up to +50 °C
Front plate
Aluminum
Width
100 mm
Height
80 mm
Depth
80 mm
Weight
80 g
The right to effect technical modifications is reserved!
CP F
CP F
I
II II
III III
Mainswitch 12 V
Mainswitch 12 V
1

Publicidad

Tabla de contenido
loading

Tabla de contenido