7
Brief description of the press device
7.1 Automatic press cycle (Fig. 1)
The device features an automatic press cycle. This ensures that the pressing operation is always
completed. The automatic press cycle is only activated after approx. 1 second. After the automatic
press cycle has been triggered, the green LED (2) goes out and the pressing operation runs
automatically. The pressing operation can then only be stopped by pressing and holding release
button (5). After the pressing operation has been completed, the motor automatically switches off and
the green LED (2) lights up again.
If the start button (1) is released before the automatic press cycle begins, the piston in the press
device moves back to its starting position. The pressing operation will not have been completed. The
pressing operation must be triggered again.
Pos : 29 /RVT/Kurz bes chr eibung/Entlastungs knopf/AC O102, ACO152, AC O/ECO202, AC O202XL @ 0\mod_1382425726244_18.doc x @ 1401 @ 2 @ 1
7.2 Release button (Fig. 1)
The pressing operation can be stopped at any time by pressing and holding the release button (5).
The piston in the press device then returns to its starting position.
Pos : 30 /RVT/Kurz bes chr eibung/Pressstellenbel euc htung/AC O103 @ 4\mod_1516954280553_18.doc x @ 33893 @ 2 @ 1
7.3 Pressing point lighting
When the start button (1) is pressed, the pressing point is lit by 1 LED (12). If the press device is out of
use for a longer period, the device and the LED switch off.
Pos : 31 /RVT/Kurz bes chr eibung/F unksc hni ttstelle/Funks chnittstell e - AC O103 BT @ 5\mod_1519224527025_18.doc x @ 34906 @ 2 @ 1
7.4 Wireless interface (Fig. 1)
The device ACO103 BT features a wireless interface.
This wireless interface together with the NovoCheck app can be used to connect the ACO103 BT to a
mobile terminal device, such as a smartphone, tablet, etc. (Android, IOS; further information at
www.novopress.de). The following functions are available:
•
Reading the press device
•
Checking the press device
•
Making settings
•
Generating construction site reports.
To establish a connection, the press device must be operational and the NovoCheck app installed on
the terminal device.
The press device can now be connected with the NovoCheck app. (For more information, go to
www.novopress.de) When the connection to the wireless interface was established successfully, the
blue LED (10) lights up.
The blue LED (10) goes out if no connection has been established until the first pressing operation is
performed. A new attempt to establish the connection can only be made if the press device has been
switched off in the meantime. It may be necessary to pull the rechargeable battery for this.
If you do not wish to establish a connection, press the start button (1) once again and perform the
pressing operation.
Pos : 32 /RVT/Kurz bes chr eibung/Akku allgemei n/Ü bers chrift/AC O102, ACO152, ACO202XL, AXI/AAP102, @ 0\mod_1382447195475_18.doc x @ 1453 @ 2 @ 1
7.5 Battery
Pos : 33 /RVT/Kurz bes chr eibung/Akku allgemei n/Info: nic ht geladen + T emperatur en/AC O102, ACO152, AC O/ECO202, AC O202XL, AF P/EFP202, AXI/AAP102 @ 2\mod_1469431352019_18.doc x @ 21590 @ @ 1
Information!
The batteries are not charged at the factory.
Therefore:
–
Information!
Limited temperature range for charging and storing the batteries.
Therefore:
–
Pos : 34 /RVT/Kurz bes chr eibung/Akku allgemei n/Akku abnehmen + aufsetzen/ACO102, ACO152, AC O/ECO202, AC O202XL, AF P/EFP202 @ 0\mod_1382442983216_18.doc x @ 1433 @ @ 1
Charge the batteries before using for the first time.
It is imperative that the operating instructions for the battery charger are complied
with.
15
ACO103 BT
EN