Stopwatch Feature; Test Feature; Key Lock; Specifications - Monacor CS-50CU Manual De Instrucciones

Ocultar thumbs Ver también para CS-50CU:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

5.6 Stopwatch feature

In addition to the clock, the controller offers a stop-
watch feature .
1) To change from the clock indication to the stop-
watch mode, briefly press the button SET (8) . The
display (5) will show in the lower line
Counter
0:00:00
2) Start the stopwatch feature with the button
(6) . The indication will change to
and the time indication will start counting .
3) After the time to be measured, press the but-
ton
once again . The indication will change
to
and the time indication will stop .
Stopped
4) To reset the stopwatch after stopping, press the
button
(7) .
5) By briefly pressing the button SET, it will be possi-
ble at any time – even while the stopwatch keeps
counting – to switch to the indication of the time
and back to the stopwatch mode .

5.7 Test feature

To test if all microphone stations are connected:
1) Press the button SET (8) for approx . 2 seconds .
Instead of the date,
the setting menu is activated .
2) Press the button
is indicated . The LEDs (23) and
System Test
rings (22) of all microphone stations connected
will light up; however, the microphones will
remain switched off .
3) To exit the setting menu, press the button
repeatedly until
the button SET .

5.8 Key lock

To prevent inadvertent actuation of buttons, a
key lock feature is provided . When the key lock
is activated,
will appear on the top right of the
display (5) and the stopwatch feature will not be
available . For normal operation, the key lock must
be deactivated again .
To activate /deactivate the key lock feature:
1) Press the button SET (8) for approx . 2 seconds .
will flash on the display .
SET
2) If
fails to appear on the display im-
Key Lock
mediately, press the button
is indicated . Confirm with the but-
Key Lock
ton SET .
3) Select
with the button
Yes
lock or
with the button
No
key lock . Confirm with the button SET .
Counting
will keep flashing while
SET
(6) or
(7) repeatedly until
is indicated, then press
Exit
(6) or
to activate the key
to deactivate the

6 Specifications

Controller CS-50CU
Number of microphone
stations: � � � � � � � � � � � � � � 50 max�
Maximum cable length: � � � 100 m
RCA inputs "Line in", "Telephone in", "Insertion in"
Sensitivity: � � � � � � � � � � � 200 mV
Maximum level: � � � � � � � 3�5 V
Impedance: � � � � � � � � � � 33 kΩ
RCA input "Recorder in"
Sensitivity: � � � � � � � � � � � 100 mV
Maximum level: � � � � � � � 1�8 V
Impedance: � � � � � � � � � � 47 kΩ
XLR input "Microphone"
Sensitivity: � � � � � � � � � � � 1�6 mV
Maximum level: � � � � � � � 2 V
Impedance: � � � � � � � � � � 1�3 kΩ
Phantom power supply: � 12 V (⎓) ±1 V via 2 × 680 Ω
RCA outputs "Line out", "Telephone out", "Insertion out"
Rated output level: � � � � � 200 mV
Maximum output level: � � 3�5 V
Impedance: � � � � � � � � � � 500 Ω
RCA output "Recorder out"
Rated output level: � � � � � 32 mV
Maximum output level: � � 1 V
Impedance: � � � � � � � � � � 500 Ω
Power supply: � � � � � � � � � � 100 – 264 V/ 50 – 60 Hz
Power consumption: � � � � � 90 VA max�
Ambient temperature: � � � � 0 – 40 °C
Dimensions: � � � � � � � � � � � 360 × 150 × 90 mm
or
Weight: � � � � � � � � � � � � � � � 1745 g
Microphone stations CS-50CH and CS-50DU
Type of microphone: � � � � � back electret
Pick-up pattern: � � � � � � � � � cardioid
Frequency range: � � � � � � � � 50 – 18 000 Hz
Max� SPL: � � � � � � � � � � � � � 125 dB at 1 % THD
Cable length: � � � � � � � � � � � 2�1 m
Dimensions
(without microphone): � � � � 170 × 115 × 65 mm
Length of gooseneck: � � � � 400 mm
Weight: � � � � � � � � � � � � � � � 1100 g
Subject to technical modification .
(7) until
All rights reserved by MONACOR
& Co. KG. No part of this instruction manual may be repro­
duced in any form or by any means for any commercial use.
(25 per connection)
INTERNATIONAL GmbH
®
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cs-50chCs-50du17.342017.341017.3430

Tabla de contenido