Technical data

Poor cooling, interior temperature increases
Fault
Compressor runs for a
long time/continuously
Compressor runs
intermittently
Unusual noises
Fault
Loud humming
12
Technical data
Item number:
Voltage:
Capacity:
Average power consumption:
Cooling temperature range:
Relative humidity:
Constant inclination:
Dimensions (WxHxD) in mm:
Weight:
Test/certificates:
Versions, technical modifications and delivery options reserved.
The coolant circuit contains R134a.
34
Possible cause
Vaporiser is iced over
Ambient temperature too high
Insufficient ventilation and/or air sup-
ply
Condenser is dirty
Fan defective (if installed)
Battery capacity exhausted
Possible cause
A component of the refrigerant circuit
cannot move freely (touching the wall)
Foreign body jammed between the
cooling unit and the wall
Fan noise (if installed)
Remedy
Defrost the vaporiser
Move the freezer to
another location
Clean the condenser
Replace the fan
Charge the battery
Remedy
Bend the component
carefully away from the
obstruction
Remove the foreign body
CRF-0050E
12 V DC or 24 V DC
47 l
45 W
0 °C to max. -18° C
maximum 90%
max. 30°
448x527x543
25 kg
complies with ErP/EuP directive
CoolMatic CRF-50