Technical data
Pump-up portable sprayers
Max. capacity in litres:
Max. operating temperature:
Empty weight:
Hollow cone nozzle:
Angle of spray:
Quantity reyuired by 1,5 bar:
by 2,0 bar:
by 2,5 bar:
Tank material:
Pump material:
Mesh size of filter in
quick-connecting valve:
Filler funnel strainer
mesh size:
Residue when emptied
horizontally:
Configuration:
- Container made of stainless steel
- all-plastic quick-connecting valve with integreated
pressure gauge
- Brass spray pipe with adjustable cone nozzle 1 mm
- Extension pipe 505 mm long
- Two adjustable padded carrying straps
- Pump lever with spray lance park facility
6
Important Safety Precautions
●
GLORIA pump-up portable sprayers are used to
protect plants. They should only be used to apply
BBA-approved plant protective agents.
●
Protect the unit against prolonged exposure to the
sun and against frost.
●
For safety reasons, do not attempt to spray explo-
sive substances, corrosive liquids, disinfectants
and impregnating agents or any materials over
40°C.
●
Carefully follow the instructions of the manufactur-
er of the substance to be sprayed. If necessary,
wear protective clothing.
●
Do not prepare more of the spraying mixture than is
immediately required. (Do not pour any leftover
Typ 2016
amounts down the drain.) Dilute any leftover solu-
16
tions 1:10 and pour it onto ground that has been cul-
tivated.
+ 40°C
●
3.85 kg
Do not eat, drink or smoke while working with plant
protective agents and pesticides until you have fin-
ished the work, removed your protective clothing,
55°
carefully cleaned your hands and face, and rinsed
0.42 l/min
out your mouth.
0.49 l/min
●
Do not clear blocked nozzles by blowing through
0.50 l/min
them.
Polyäthylen
●
Do not hold the end against you when undoing the
Polyäthylen
spray tubes.
●
Warning!
0.9 mm
We hereby state explicitly that we accept no liability
as per the Product Liability Law for any damage or
1 mm
injury caused by our equipment insofar as this was
caused by inappropriate repairs or by using
ca. 70 ml
replacement parts that were not GLORIA original
spare parts and if the repairs were not carried out
by our Customer Service section or an authorized
technician. This also applies to accessories.
Safety instructions
(Explanation of the pictograms)
I
Before initial operation read and observe operating
instructions and safety information!
Observe the instructions of the manufacturer
of the spraying agent!
II
Wear protection gloves if necessary!
III Wear protection clothes if necessary!