brennenstuhl BCN 1221 Manual De Instrucciones página 27

Ocultar thumbs Ver también para BCN 1221:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 101
BCN 1221
Operating Instructions
ALARM SIGNAL & LED- DISPLAY
Note:
means "peep, peep, peep"
I I I
Detektor function
Green
Red
Energy display
Alarm signal
Power
Alarm
Normal operation
Blinks once per
-
Minute ☼
-
Alarm condition
4 peeps +
blinks ☼
Mute function (Hush)
-
4 blinks ☼
under alarm and alarm
conditions
Pre-alarm signal CO
-
Single blink
Level (40 ppm or
every 8 se-
higher concentration
cond until
detected)
Alarm ☼
Memory function
-
-
shows that the alarm
was active for some
reason (not from test
button)
Empty battery –
-
-
warning
Sensor fault
-
-
Warning: End of
-
sensor's operational
lifetime
Yellow
Alarm Sond
Fault signal
Fault
-
-
-
■ ■ ■ ■ - 1s -
■ ■ ■ ■ - 1s -
■ ■ ■ ■ ...
-
-
-
-
-
■ -- 8s --
■ -- 8s -- ■
1 peep every 8 se-
conds.Press but-
ton once to return
to normal mode
1 peep + blink
■ - 1 min -
per minute ☼
■ - 1 min -
■ ...
2 peeps + blinks
■ ■ - 8s -
every 8 seconds
■ ■ - 8s -
■ ■ - 8s - ...
3 peeps + blinks
■ ■ ■ - 1 min -
every minute ☼
■ ■ ■ - 1 min -
■ ■ ■ ...
27