Multiple Faults; Missing Remote - AEMC Instruments Wire Mapper Pro CA7028 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.9

Multiple Faults

In the event of a multiple fault, or a cable or link with more than one fault on
it, the tester will report the faults in the following order of priority.
• Shorts
• Reversals
• Opens
For example, on a cable with an Open on pin 3 and a Short between
pins 7 and 8, only the Short in pins 7 and 8 will be reported.

4.10 Missing Remote

If a wire map test is performed without a remote unit connected at the far
end, the following screen will be displayed:
Wire Mapper Pro Model CA7028
? ? ? ? ? ? ? ? ? ? ? ? ? ? ?
Missing
Remote Unit
? ? ? ? ? ? ? ? ? ? ? ? ? ? ?
17