Vacuum clamping unit VAC SYS SE
Table of contents
1
Symbols
2
3
Machine features
4
Intended use
5
5.1
5.2
6
6.1
6.2
7
8
9
10
11
12
13
1
Symbols
Warning of general danger
Electric shock
Read the operating instructions/
notes
Advice or tip
The specifi ed illustrations are at the begin-
ning of this operating manual.
2
Technical data
Vacuum pump end pressure abs. 150 mbar
Weight of vacuum clamping
unit SE 1
Weight of vacuum clamping
unit SE 2
Protection class
Holding force of the vacuum clamping
unit
Suction
plate
D 215
275x100
Maximum workpiece dimensions
Suction
plate
D 215
275x100
200x60
277x32
Specifi cations for smooth surfaces such as PMMA (plexi-
1
glas
), PF hard fi bre (Resitex) and worktops, not for MDF
®
or similar materials.
The holding force may decrease by up to 20% over the
2
course of the years. Values relate to a vacuum of 85%
(150 mbar end pressure) and include a safety factor of 2.
3
Machine features
[1-1] Mains connection
[1-2] On/off switch
[1-3] Vacuum gauge
[1-4] Ventilation slits
[1-5] Vacuum connection
[2-1] Slide valve
[2-2] Rotary knob for clamping the suction
plate
[2-3] Locking pin for suction plate
[2-4] Clamp lever for tilting fi xture
[2-5] Foot valve
[2-6] Suction plate
8.3 kg
4
Intended use
8.1 kg
The vacuum clamping unit VAC SYS SE is
/ II
designed for clamping objects with fl at,
smooth, airtight surfaces in combination
with vacuum pump VAC SYS VP.
The user bears the responsibility for damage
and accidents caused by improper use.
13
Holding force
Holding force
0° tilted
90° tilted
1, 2
(workpiece
(workpiece ver-
horizontal)
tical) [kg]
[kg]
55
35
22
21
Maximum di-
Maximum
mensions
[m]
weight
1
1 x 1
1.2 x 0.4
0.8 x 0.2
1.2 x 0.08
1, 2
90
53
30
27
[kg]
1
30
20
10
8