Descargar Imprimir esta página

Machine Storage; Troubleshooting; Repairs; Environmental Protection - Metabo Mega 370/100 W Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 41
58
Every 1000 operating hours
Have unit serviced by an authorised
service centre. This will extend the
compressor's service life considerably.
6.2

Machine storage

1. Switch unit OFF and unplug.
2. Release pressure from tank and all
connected air tools.
3. Drain condensate from pressure
vessel .
4. Store device in such way that it can-
not be started by unauthorised per-
sons.
A
Caution!
Do not store or transport machine un-
protected outdoors or in a damp envi-
ronment.
Do not lay machine on its side for trans-
port or storage.
7.

Troubleshooting

A
Danger!
Prior to all servicing:
– Switch machine OFF.
– Unplug power cable.
– Wait until the compressor has come
to a complete stop.
– Ensure the compressor and all air
tools and accessories connected to
it are relieved from pressure.
– Let the device and all air tools and
accessories cool down.
After all servicing:
– Reactivate all safety devices and
ensure they are operational.
– Make sure that no tools or other
parts remain on or in the machine.
Compressor does not run:
No mains voltage.
– Check cables, plug, outlet and
mains fuse.
Mains voltage too low.
– Use only extension cables of suf-
59
ficient lead cross section (see
'Technical Data'). When the ma-
chine is cold avoid extension ca-
bles and relieve the pressure in
the pressure tank.
Compressor was stopped by un-
plugging.
– Switch compressor OFF and
then ON again using the On/Off
switch.
Motor has overheated, e.g. due to
insufficient cooling (cooling fins cov-
ered).
– First switch off the compressor
using the ON/OFF switch and al-
low to cool.
– Eliminate the cause of overheat-
ing.
Only for version with AC motor:
– Check the motor protection
switch; reset if necessary.
– Switch the compressor back on.
Compressor runs but does not build
up sufficient pressure.
Condensate drain cock of pressure
tank leaky.
– Check gasket of drain cock(s);
replace if necessary.
– Tighten drain cock(s) hand-tight.
Check valve leaky.
ENGLISH
– Have check valve serviced by
qualified service centre.
Air tool is not supplied with suffi-
cient pressure.
Pressure regulator not opened wide
enough.
– Open pressure regulator more.
Hose connection between compres-
sor and air tool leaky.
– Check air hoses; replace defec-
tive parts if necessary.
Further work on the machine should
only be carried out by a qualified
electrician or the Service Centre in
your country.
8.

Repairs

A
Danger!
Repairs to electric tools must be carried
out by qualified electricians only!
Electric tools in need of repair can be
sent to the Service Centre in your coun-
try. See Spare Parts List for address.
Please attach a description of the fault
to the power tool.
9.
Environmental Protec-
tion
A
Danger!
The condensation water from the pres-
sure vessel contains oil residues. Dis-
pose of the condensation water in an
environmentally-oriented manner at an
appropriate collection point!
A
Danger!
Dispose of the waste oil from the com-
pressor pump in an environmentally-ori-
ented manner at an appropriate collec-
tion point!
The tool's packaging can be 100% re-
cycled.
Worn out machines and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on paper
produced with an elemental chlorine-
free bleaching process.
15

Publicidad

loading