Installation Instruction - Whirlpool SPIW409A2WF Instrucciones De Uso

Ocultar thumbs Ver también para SPIW409A2WF:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 48

Installation instruction

Installation diagram
Distance from wall
should be over 50mm
Indoor unit
Distance from floor
should be over 2500mm
Outdoor unit
Air intake distance from
the wall should be over
250mm
When install interconnection cord, make sure that the color of wires and the terminal No. of outdoor unit shall be
same as those in indoor unit.
Cable Specifications
Capacity (Btu/h)
7K, 9K, 12K
18K
24 K
Distance from ceiling
should be over 200mm
Power cord
Normal cross -
Type
sectional area
H07RN-F
1.0mm
H07RN-F
1.5mm
H07RN-F
2.5mm
- 12 -
To get detail installation information, please go to:
docs.whirlpool.eu
Distance from the wall
should be over 50mm
Distance from the wall
should be over 50mm
NOTE: The figure is only a simple presentation of the
unit, it may not match the external appearance of the
product you purchased. Installation must be performed
in accordance with the national wiring standard by
authurized service people only.
Air intake distance from
the wall should be over
250mm
Over 250mm
Power connecting cord
Type
X3
H07RN-F
2
X3
H07RN-F
2
X3
H07RN-F
2
Normal cross -
sectional area
1.0mm
X5
2
1.5mm
X5
2
2.5mm
X5
2

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido