Descargar Imprimir esta página

Velleman HAA263D Manual Del Usuario página 6

Panel de control resistente a la intemperie
Ocultar thumbs Ver también para HAA263D:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

• HOME mode is only available for use with USER CODE 3 (whole system). However, partitions
can be bypassed by bypassing the zones within the partition one by one.
• Zone 8 (24 hour zone) is excluded from use in HOME mode
• Format:
HOMEyyyyyy#
HOME
yyyyyy =
# =
• To use the home mode, simply type USER CODE 3,
automatically be bypassed.
c. Keypad audible notification set-up
• Some audible notification can be passed on to the keypad. This is the case for the exit and entry
delay, after an alarm condition and for each key button press.
• Alarm conditions concerning battery low or AC power failure conditions are always ON.
• Passing these notifications through to the keypad will not affect the beep settings on the master
control unit.
• Note that confirmation beeps from the
14yyyy#
14
yyyy =
# =
d. Alarm detection response time
The default zone response time is set to 500ms. This setting can be adjusted independently per
zone, depending on the conditions in that zone.
The 8 digit code represents the 8 protection zones. The first digit is zone 1 and the last digit is
zone 8. By putting the timing codes into the specific digit to independently the desired response
time can be set.
15yyyyyyyy#
14
yyyyyyyy =
# =
e. Reset system to default
To reset the system to its default values, enter code 2100#.
Except for the master code, all other values will be cleared or set to their default.
f. Exit programming mode
To leave programming mode, type
8. Operation
This system is designed with "FORCED TO ARM" operation. If faulty zones exist it will bypass the
faulty zones automatically after it is armed. The LED of the faulty zones will flash to indicate that
they are not protected and the "FORCED TO ARM" LED will also flash to indicate that the system is in
"Forced To Arm"-mode with the faulty zones bypassed.
a. Arm the system with exit delay
02 (15/11/2013)
HAA263D
Press HOME button on keypad
List of zones to be enabled, sequential e.g. 245 to
bypass zones 2, 4 and 5
validation
-button and
master code
4 digits: 0=beep disabled, 1=beep enabled (default)
digit 1
Beep for exit delay
digit 2
Beep for entry delay
digit 3
Beep after alarm condition
digit 4
Beep after each key button press
validation
master code
8 digits, default setting = 3
1
25 ms
2
250 ms
3
500 ms
4
750 ms
validation
.
6
and
; all programmed zones will
-button are always enabled.
VELLEMAN

Publicidad

loading

Este manual también es adecuado para:

Ham263d