Make sure that the alarm system is in disarmed mode and the alarm memory is empty. If the
memory is not empty, clear it first (see below).
•
Enter an appropriate USER CODE and validate with
•
2-beeps confirm correct code entry, exit delay starts and EXIT/ARMED LED flashes.
•
5-beeps indicate incorrect code entry. Enter the code again.
•
System will arm after exit delay expires. The appropriate partition LED and the EXIT/ARMED LED
are ON.
b. Arm the system instantly
•
Make sure that the alarm system is in disarmed mode and the alarm memory is empty. If the
memory is not empty, clear it first (see below).
•
Enter an appropriate USER CODE,
•
2-beeps confirm correct code entry and the system arms instantly without exit delay. The
appropriate partition LED and the EXIT/ARMED LED are ON.
•
5-beeps indicate incorrect code entry. Enter the code again.
Note: as there is no exit delay, walking through the protected area will trigger the alarm. Mount
the keypad outside the protected zone to use this function.
c. Arm the system in home mode with exit delay
•
This function only works with USER CODE 3. The protection zones that are stored in memory will
be bypassed when arming.
•
Enter USER CODE 3,
•
2-beeps confirm correct code entry, exit delay starts and EXIT/ARMED LED flashes.
•
5-beeps indicate incorrect code entry. Enter the code again.
•
The LEDs indicating the bypassed zones will flash constantly.
•
System will arm after exit delay expires. The appropriate partition LED and the EXIT/ARMED LED
are ON.
Note: in HOME mode, USER CODE 1 and 2 can still be used to disarm the partitions.
d. Arm the system in home mode instantly
•
This function only works with USER CODE 3. The protection zones that are stored in memory
will be bypassed when arming.
alarms.
•
Enter USER CODE 3,
•
2-beeps confirm correct code entry and the system arms instantly without exit delay.
e. Arm the system with manual bypass
•
This function allows the temporary bypassing of protection zones, e.g. faulty zones.
•
USER CODE 1 can only bypass zones in partition 1 while USER CODE 2 can only bypass zones
in partition 2. With USER CODE 3, all zones can be bypassed.
•
Make sure that the alarm system is in disarmed mode and the alarm memory is empty. If the
memory is not empty, clear it first (see below).
•
Enter the appropriate USER CODE,
.
•
2-beeps confirm correct code entry, exit delay starts and EXIT/ARMED LED flashes.
•
5-beeps indicate incorrect code entry. Enter the code again.
•
The LEDs indicating the bypassed zones will flash constantly.
•
System will arm after exit delay expires. The appropriate partition LEDs and the EXIT/ARMED
LED are ON.
• The manual setting of bypassed zones is lost when the system is disarmed.
f. Disarm the system
•
Simply enter an appropriate USER CODE and
• The system disarms instantly.
•
2-beeps confirm correct code entry.
• 5-beeps indicate incorrect code entry. Enter the code again after the beeps.
g. Clear the alarm memory
Before the system can be re-armed in a normal way, the alarm memory must be cleared.
02 (15/11/2013)
HAA263D
,
and
The bypassed zones are not monitored and will not trigger alarms.
and
.
The bypassed zones are not monitored and will not trigger
,
and
.
, the zone numbers that need to be bypassed
7
key.
.
within the entry delay period.