First launch
1.
Switch off the mains voltage.
2.
Open the wall switch box.
3.
Disconnect the wiring from the switch.
4.
Switch on the mains voltage.
DANGER OF ELECTROCUTION:
5.
Identify the Live wire using voltage tester.
6.
Switch off the mains voltage.
7.
Connect Live wire to L terminal and power
terminal of switch.
8.
Connect Neutral wire to N terminal.
9.
Connect Load wire to Q terminal.
10. Connect S1 terminal to button terminal of switch.
11. Put device and wires in and close
the wall switch box.
12. Switch on the mains voltage.
13. Open the FIBARO app and tap
14. Application will guide you through
the pairing process.
Setup code
You will find the Setup Code on the back of this guide.
Remember to keep it in a safe place. You may need it in case of re-pairing.

Resetting to factory defaults

DANGER OF ELECTROCUTION:
1.
Open the wall switch box.
2.
Press and hold the button.
3.
When the LED glows yellow, release the button.
4.
Click the button again to confirm.
Descriptions for wiring diagrams
icon.
8
Live wire
1
Neutral wire
2
Load wire
3
4
Switch button wire
5 Switch power wire
Triple wire connector
Wire colours are only indicative,
consult electrician to make sure
which wire is which.