When more than one transmitter is used:
1.
User shall remove all the batteries from the weather station and transmitters and wait
for 60 seconds if setting has been done with one transmitter before.
2.
Insert the batteries to the first transmitter.
3.
Within 25 seconds of powering up the first transmitter, insert the batteries to the
weather station. Once the batteries are in place, all segments of the LCD will light up
briefly. Following time as 0:00 and the weather girl icon will be displayed. If they are
not shown in LCD after 60 seconds, remove the batteries and wait for at least 60
seconds before reinserting them.
4.
The outdoor temperature from the first transmitter (channel 1) should then be
displayed on the weather station. Also, the signal reception icon will be displayed. If
this does not happen after 2 minutes, the batteries will need to be removed from both
units and reset from step 1.
5.
Insert the batteries to the second transmitter as soon as the outdoor temperature
readings from the first transmitter are displayed on the weather station.
Note: User shall insert the batteries into the second transmitter within 10 seconds of
reception of the first transmitter.
6.
The outdoor data from the second transmitter and the "channel 2" icon should then be
displayed on the Weather station. If this does not happen after 2 minute, the batteries
will need to be removed from all the units and reset from step 1.
7.
Insert the batteries to the third transmitter as soon as the "channel 2" icon and outdoor
data are displayed on the weather station. Then within 2 minutes, the channel 3
52