Service And Maintenance; After Finishing Work - Festool CTL 48 E LE EC/B22 R1 Manual De Instrucciones

Ocultar thumbs Ver también para CTL 48 E LE EC/B22 R1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 30
CT B22
GB
Observe the following when extracting dust gener-
ated by operating electric power tools:
If the exhaust air is discharged back into the room,
the air renewal rate L within the room must be suf-
ficient. The volume of air discharged back into the
room must not exceed 50% of the fresh air volume
flow (room volume V
R
serve all the relevant regional regulations.
Remember: A moist main filter clogs more quickly
when extracting dry materials. Therefore, dry the
main filter before extracting dust or replace the
damp filter with a dry one.
8.3
Extracting fluids
Before extracting fluids, remove the filter bag (see
Chapter 7.8). We recommend using a special wet
filter.
The dust extractor stops automatically when the
maximum level is reached.
CAUTION
Escaping foam and fluids
Switch off the machine immediately and empty
the dirt trap.
8.4

After finishing work

Empty the mobile dust extractor after every
use and clean if necessary.
Switch off the mobile dust extractor and pull out
the mains plug.
Wind up the mains power cable.
Empty the dirt trap.
Close off the extractor opening [1-2] using the
sealing plug [1-1].
WARNING
Hazardous dust
Damage to the respiratory passage
Wipe down the mobile dust extractor and clean
all accessories thoroughly using the extractor
(inside and out) before removing from the work-
ing area.
Parts that you were not able to clean thoroughly
must be sealed in an airtight plastic bag prior to
transportation.
Wear a dust mask!
The machine shall be stored indoors only.
20
x air renewal rate L
W
Place the mobile dust extractor in a dry room in-
accessible to unauthorised users.
9

Service and maintenance

). Ob-
Risk of injury, electric shock
Always disconnect the mains plug from the
socket before performing maintenance work on
the machine!
All maintenance and repair work which requires
the motor housing to be opened must only be
carried out by an authorised service workshop.
Damaged safety devices and components must be
repaired or replaced in a recognised specialist
workshop, unless otherwise indicated in the oper-
ating manual.
Observe the following instructions:
– A dust test must be performed at least once a
year by the manufacturer or an instructed per-
son. This test may include checks to determine
whether the filter is damaged, the machine is
sealed properly and the monitoring features are
functioning correctly.
– During maintenance and repair work, all compo-
nents that cannot be cleaned satisfactorily must
be replaced. The old components must be sealed
in impermeable plastic bags prior to disposal in
compliance with applicable regulations for this
type of waste.
– Provided maintenance personnel or other per-
sons in the vicinity are not endangered, the user
must dismantle and clean the machine prior to
performing maintenance work. Appropriate pre-
cautionary measures include decontaminating
the machine prior to disassembly, making provi-
sions for locally filtered forced ventilation at the
location of machine disassembly, cleaning the
maintenance area and appropriate personal pro-
tective equipment.
EKAT
4
5
3
2
1
WARNING
Customer service and repair only
through manufacturer or service
workshops: Please find the nearest
address at: www.festool.com/service
Only use original Festool spare parts!
Order No. at: www.festool.com/service

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ctm 48 e le ec/b22 r1Ctl 48 e le ec/b22Ctm 48 e le ec/b22

Tabla de contenido