3. Push the cut end of this "intake" hosing into the rubber connector on the intake tube. Push the hosing in by at least 1 in. (2.5
cm) without twisting it.
IMPORTANT:
Hosing must follow a straight path with no kinks or loops and very little slack.
If the hosing is too long, the filter will not work properly.
The factory-finished end of the hosing must connect to the AquaStop valve.
To ensure a watertight seal, the cut end of the hosing, which connects to the
intake assembly, must be kept under water.
4. Clip the suction cup onto the intake assembly near the strainer and place the assembly in
the tank, making sure the strainer is at least 3 in. (7.5 cm) from the bottom. (If the tube is too
long for the height of your aquarium, remove the strainer from the intake assembly, cut the
tube with a hacksaw, and then replace the strainer.) Once the intake assembly is properly
positioned, lock it in place by pressing the suction cups against the glass.
5. Position the top half of the rim connector assembly over the hosing and push down until it
"clicks" to lock the hosing in place.
4. Prepare output connections
1. The remaining length of hosing will be used for output. Attach the hosing to the output connector
(OUT) on the right side of the AquaStop valve.
a. Push the factory-finished end of the hosing onto the valve; push it all the way, as far as it will
go.
b. Turn the lock nut counter clockwise until it is as tight as you can make it without forcing.
2. Measure and cut the hosing. Again, you will need a length of hosing that reaches comfortably
from the filter canister to inside the aquarium.
a. Stretch out the hosing so it rests over the "output" rim connector assembly.
b. At a spot about 4 in. (10 cm) beyond the aquarium rim, use a utility knife to cut the hoseDo
not cut the hose too short. Remember, you can always cut it shorter during final installation,
if necessary.
IMPORTANT: Remember, to maintain a watertight seal, the connection point between the
hosing and the output nozzle should be kept below the water line.
3. Push the cut end of this "output" hosing into the rubber connector at the top of the output
nozzle assembly. Push the hosing in by at
least 1 in. (2.5 cm) without twisting it.
4. Place the output nozzle in the tank about
0.8 in. (2 cm) below the anticipated final
water level; then push the top half of the rim
connector assembly down until it "clicks" to
lock the hosing in place.