Instructions for installation and operation
Filtration • Filtración • Filtration • Filtração
directly downstream of compressor
directamente detrás del compresor
directement en aval du compresseur
imediatamente após o compressor
downstream of receiver
detrás del depósito
en aval de la cuve
após a bacia
downstream of refrigeration dryer
detrás del secador frigorífico
en aval du sécheur frigorifique
após o secador frigorífico
26
DRYPOINT DM 10-34 C-N, DM 10-41 C-N, DM 10-47 C-N, DM 20-48 C-N, DM 20-53 C-N, DM 20-60 C-N, DM 20-67 C-N,
oil-lubricated / lubricado por aceite
lubrifié à l'huile / lubrificado a óleo
oil-free / sin aceite
non huileux / não oleoso
oil lubricated / lubricado por aceite
lubrifié à l'huile / lubrificado a óleo
oil-free / sin aceite
non huileux / não oleoso
oil lubricated / lubricado por aceite
lubrifié à l'huile / lubrificado a óleo
oil-free / sin aceite
non huileux / não oleoso
1
2
4. Installation
Risk of serious or even fatal injury from 
contact with quickly or suddenly escap-
ing compressed air, or from bursting plant 
components.
Preventive action:
• Avoid sudden and quick opening of 
shut-off devices!
• Do not exceed the maximum permissi-
ble operating pressure and temperature 
(see type plate)!
• Make sure that no persons or objects 
can be damaged by escaping com-
pressed air or condensate.
•   O nly use pressure-resistant installation 
material!
For installation and maintenance work, 
wear appropriate personal protective 
equipment (safety goggles, light breathing 
protection, protective gloves, and hearing 
protection).

4.1 Installation requirements

Particles, oil and condensate must be reli-
WS
Filter F
ably removed from the compressed air. To 
achieve this, a CLEARPOINT
x
x
(0.01 µm) is integrated into the housing 
x
of the membrane dryer. At high levels of 
4
contamination or where large volumes of 
x
condensate occur, it might be necessary 
to install additional CLEARPOINT
filters (1 µm) and CLEARPOINT
separators.
For the prefiltration requirements, see fig-
ure to the left.

4.2 Installation instructions

• To facilitate maintenance, we recom-
mend installing a bypass line (1).
• The purge air outlet covered with a 
screen (2) must not be obstructed.
• The installation room must be free of 
chemical substances, and no such sub-
stances must be released by other 
equipment installed near the device.
• The device must be installed in a room 
where the ambient and the compressed
air temperature does not exceed the
permissible range of +35 to +140 °F.
• Clean the pipeline system thoroughly.
(If necessary, blow it out.)
• Seal all threads with Teflon tape.
--> Do not use liquid sealants.
• Position the device so that the filter can 
be replaced easily and without causing 
damage to the membrane dryer.
DM 40-61 C-N, DM 40-75 C-N, DM 40-90 C-N
US-EN
DANGER!
Escaping compressed air!
Caution!
Risk of injury!
 nanofilter 
®
 fine 
®
water
®