Instalation
Specification of the cables for proper installation:
• Power connectors (positive/negative)
• Remote connector
• Output signal connectors (speakers)
• Fuses or circuit breakers
The use of fuse or circuit breaker is mandatory to protect the system from short
circuit and overload. Install them as close to the battery as possible.
Installation should only be done by qualified professionals with the
product turned OFF.
POSITIVE:
00 AWG cable
Fuse
400A
Battery
RECOMMENDED USE
OF AUXILIARY BATTERY.
......................................................................
..............................................................
NEGATIVE:
00 AWG cable
15
........................................
..........................................
00 AWG
20 AWG
7 AWG
400A
REM
Remote: 20 AWG