EASY DIAGNOSTIC INDICATORS
120V 15 A and 20 A ONLY.
120V 15 A and 20 A ONLY.
208 V / 240 V 15 A, 20 A and 30 A ONLY
208 V / 240 V 15 A, 20 A and 30 A ONLY
If the "L-N OK" GREEN light is displayed, protection is in effect.
If the ''L-N OK" GREEN light is blinking, protection is not in effect.
The equipment will be disconnected. Call an electrician to correct
the wiring in the building or outlet.
If the ''PROTECTED" GREEN light is displayed, protection
is in effect.
If the ''PROTECTED" GREEN light is blinking, protection is not in
effect. The equipment will be disconnected. Call an electrician to
correct the wiring in the building or outlet.
If the ''Ground OK'' GREEN light is on, the outlet
is properly wired and grounded.
If the "Ground OK" GREEN light is blinking, the outlet has lost
or has noisy ground connection. Call an electrician
to correct the wiring in the building or outlet.
If the "OV / UV FLT" light is OFF, the input voltage is within
safe limits.
If the "OV / UV FLT" light is RED, the input voltage is outside the
safe limits. The equipment will be disconnected.The load will
be reconnected automatically upon return to a safe limit of
voltage input.
The "OV / UV FLT" RED light will blink for 4 hours to indicate that
an over-voltage or under-voltage event has occured.
IMPORTANT: If the "OV / UV FLT" light continues to blink for more
than 4 hours, it indicates that an over-voltage or an under-voltage
event is recurring. Call an electrician to correct the situation.
If the "OC FLT" light is OFF, no over-current event has occurred.
If the "OC FLT" light is RED, an over-current has occurred.
This light will stay ON as long as the over current
condition exists.