15. Raise the wick to its highest position and tighten the
wing nuts in several steps.
16. Check the wick height. It should be 5/16 above the collar.
17. Check for the correct clearance between wick holder
and draft tube. It should be the same all around.
18a. Reinstall the tip-over switch assembly by pushing the
extinguish knob.
18b. Connect the four connectors (4EA) with the circuit
board.
19. Check the function of the tip-over safety stop by push-
ing the extinguish button to upset the pendulum.
20. Reinstall the ignition assembly.
21. Reinstall the wind cover A / B.
22. Reinstall the ignition assembly.
23. Reinstall the cabinet.
24. Tighten the 5 screws on the cabinet and reinstall the
sensor at the back of the cabinet.
25. Reinstall the combustion chamber and the fuel tank.
26. Reinstall the wick adjusting knob. Close the front plate.
Install the batteries in the battery case and fill the fuel
tank with Qlima Premium Quality Fuels. Set the tank
into the heater and wait at least 60 minutes for the
-
-
+
+
-
-
+
+
new wick to fully saturate with the fuel.
-
-
+
+
-
-
+
+
4
77
26-04-18 12:06