GE GXSF27B Manual Del Propietário página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation instructions.
Typical Installation Illustration
Soft water
120-volt outlet
24V transformer
Salt hole
cover
removed
SALT
GOES HERE
Brinewell
Optional 3-Valve Bypass Installation Illustration
Adapters for this installation are not supplied with the softener.
To order these adapters, call GE Parts 800-626-2000. (Ask for Part # WS60X10006.)
Soft water
120-volt outlet
24V transformer
6
Union (not supplied) (2)
Installation nut (2)
Copper tube, 3/4" (2)
Washer (2)
INLET
NOTE: See Drain Hose
Connections section.
Bypass valve
Inlet valve
Outlet valve
Copper
tube,
3/4" (2)
Washer (2)
Installation adapter (2) (see above)
NOTE: Threads on the installation adapters are 1"
INLET
male pipe. If 1" pipes are needed, do not use the
copper tubes and nuts included. Buy 1" pipe thread
female adapter and plumb directly to 1" threads on
installation adapters.
Hard water
Hard water to
outside faucets
Bypass Valve
• Pull out for soft water service
• Push in for bypass
NOTE: Threads on the bypass
valve are 1" male pipe. If 1"
pipes are needed, do not use
the copper tubes and nuts
included. Buy 1" pipe thread
female adapter, and plumb
directly to 1" threads.
Hard water to
outside faucets
Hard water
3-valve bypass system
For soft water service:
• Open the inlet and outlet
valves
• Close the bypass valve
For bypass hard water:
• Close the inlet and outlet
Nut (2)
valves
• Open the bypass valve
Fig. 1
CROSS-OVER
Use if water supply flows from the left.
Include single or 3-valve bypass.
Hard water
From softener
To softener
outlet
inlet
Fig. 2
Hard water
Soft water
From softener
outlet
To softener
inlet
CROSS-OVER
Use if water supply flows from
the left. Include single or
3-valve bypass.
Soft water

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Gnsf35zGxsf39b

Tabla de contenido