Multiple Awnings POWER PEAK B6 EQ-BID Instrucciones De Uso página 47

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 130
The following selection is available for lead batteries:
Cell count
1
2
3
4
5
6
ENTERING THE BATTERY CAPACITY
tically set to the corresponding 1C charge of the battery. It additionally serves as a battery
safety function. The selection shown below is available depending on the type of battery:
The value for the battery capacity is adapted to the corresponding type of battery.
type of battery
NiCd
NiMH
LiPo
LiIo
LiFe
Pb (Blei)
SETTING THE CHARGING CURRENT
ging capacity (max. 2C for lithium batteries). The processor in the battery charger limits the
maximum charging current if the maximum charging capacity is exceeded.
Operating Instructions
Power Peak ® B6 EQ-BID
Alternatively, the battery voltage can be selected in
2V-steps per cell for lead battery packs.
Battery voltage
2 Volt
4 Volt
6 Volt
8 Volt
10 Volt
12 Volt
The battery capacity can be selected in steps of 100
mAh (PB, 500 mAh). The battery capacity setting for
lithium battery packs mainly serves as the basis for
the 1C charge, i.e. the charging current is automa-
battery capacity
100 - 9900 mAh
100 - 9900 mAh
100 - 9900 mAh
100 - 9900 mAh
100 - 9900 mAh
0,50 Ah - 20,00 Ah
The charging current can be selected in steps of 0.1
A. Possible setting: 0.1 A to 5.0 A. The maximum
charging current is dependent on the number of
cells or the battery voltage and the maximum char-
15