SETTING THE DISCHARGING CURRENT
discharging capacity. The processor in the battery charger limits the maximum discharging
current if the maximum discharging capacity is exceeded.
SETTING THE ACOUSTIC SIGNAL
SETTING THE CUT-OFF TEMPERATURE
is connected to the TEMP connection on the battery charger. The range can be set from
SAVING THE SETTINGS
Operating Instructions
Power Peak ® B6 EQ-BID
The discharging current can be selected in steps of
0.1 A. Possible setting: 0.1 A to 1.0 A. The maxi-
mum discharging current is dependent on the num-
ber of cells or the battery voltage and the maximum
5 different signals are available; the signal generator
can also be switched off. A new tone is set every
time the signal sounds once to aid selection.
This value determines the battery temperature at
which a charging/discharging operation is to finish.
The prerequisite for this function is that a tempe-
rature sensor, correspondingly fitted on the battery,
The settings are saved by pressing the ENTER
button. The start display is then shown again (after
confirming FINISH) or the charge/discharge display
(after confirming START).
48
16
# 30 8561