2.3 Status display on the charger
Status display ("power
on" and "charging")
3 Technical data
Right of technical changes reserved.
Charger
Cooling
Battery
Output voltage
Length of charger supply cord
Weight of appliance
Dimensions (L x W x H)
Control
Protection class
AC supply voltage
Mains frequency
Output power
NOTE
Battery charging times are extended if temperatures are too high or too low.
Cold temperatures may result in the battery not being fully charged.
Printed: 03.12.2015 | Doc-Nr: PUB / 5170386 / 000 / 01
LED 1 and LED 2
don't light.
LED 1 blinks red,
LED 2 doesn't light.
LED 1 lights green,
LED 2 doesn't light.
LED 1 lights green,
LED 2 blinks green.
LED 1 and LED 2
light green.
LED 1 lights red,
LED 2 doesn't light.
C 4/12-50
Cooling by convection
Li-ion
10.8 V
Approx. 1.80 m
0.35 kg
90 mm x 135 mm x 60 mm
Electronic charging regulator
Electrical protection class II
(double insulated)
220...240 V
50...60 Hz
50 W
No electric power or the
charger is defective.
The battery is too hot or
too cold.
The charger is ready for
use.
The battery is charging.
The battery is fully
charged.
Charger malfunction.
en